Electrical connection
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
WARNING: THIS APPLIANCE MUST BE EARTHED.
The manufacturer declines any liability should this safety measure not be observed.
Should the appliance power supply cable need to be replaced, this must be carried out by by a Service Force repair agent (Pg 18 service and spare parts)
Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. (See picture on page 5).
The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved BS 1363/A fuse must be used.
Should the plug need to be replaced for any reason, proceed as described below. The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow | - Earth |
Blue- Neutral
Brown- Live
GREEN & YELLOW
E
| 13 A |
N | L |
|
BROWN
BLUE
P1041 | CORD CLAMP |
|
The wire coloured green and yellow must be connected
to the terminal marked with the letter «E» or by the
earth symbol or coloured green and yellow.
The wire coloured blue must be connected to the
terminal «N» or coloured black.
The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
WARNING:
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of safely.
Permanent connection
In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.
The switch must not break the yellow and green earth cable at any point.
8