Important! Information on the
electrical connection is given on the
rating plate on the inner edge of the
appliance door.
The appliance is supplied with a 13 amp plug
fitted.
In the event of having to change the fuse in the
plug supplied, a 13 amp ASTA approved
(BS1363/A) fuse must be used.
Should the plug need to be replaced for any
reason, proceed as described below.
The wires in the mains lead are coloured in
accordance with the following code:
1Green and Yellow - Earth
2Brown- Live
3Cord Clamp
4Blue- Neutral
1
2
3
4
The wire coloured green and yellow must be
connected to the terminal marked with the
letter «E» or by the earth symbol or
coloured green and yellow.
The wire coloured blue must be connected to
the terminal «N» or coloured black.
The wire coloured brown must be connected
to the terminal marked «L» or coloured red.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer sheath.
Warning! A cut off plug inserted
into a 13 amp socket is a serious
safety (shock) hazard.
Ensure that the cut off plug is
disposed of safely. Should the
appliance power supply cable
need to be replaced, this must be
carried out by our Service Force
Centre.
The appliance should not be
connected to the electrical
supply by means of an extension
cable.
Note!
When the appliance is installed the power
supply cable must be accessible.
Permanent connection
in the case of permanent connection it is
necessary that you install a double pole switch
between the appliance and the electricity
supply (mains), with a minimum gap of 3 mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current electrical regulations.
The switch must not break the yellow and
green earth cable at any point.
What to do if…
Certain problems are due to lack of simple
maintenance or oversights, which can be
solved easily without calling out an engineer.
Before contacting your local Service Centre,
please carry out the checks listed below.
28