SAFETY
ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD.
•This product must be installed and serviced by a qualified installer or service agency. Improper or incomplete installation, adjustment, alteration, service or maintenance could cause per- sonal injury, loss of life, or damage to property. Installation and service must be performed by a licensed professional dealer or contractor.
•Failure to follow safety warnings exactly could result in danger- ous operation, serious injury, death or property damage.
•When servicing your ductless system, your HVAC contractor must use factory supplied service and replacement parts. Failure to follow these instructions may result in property damages such as fire, personal injury or death. The manufacturer or seller can- not be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
•The power supply must be of proper amperage and conform with local codes.
•Don't cut or damage the power cords and control cords. Electric shock or fire could result. If they are damaged, immediately call your HVAC contractor to have your ductless system serviced.
•Do not operate your ductless system without the air filter installed. The air filter should be removed and cleaned periodi- cally to assure maximum efficiency.
•If a burning smell or smoke occurs, please turn off the power supply immediately and contact your HVAC contractor. Not doing so may cause electric shock or fire.
•Do not use flammable sprays near your ductless system. They can cause a fire or explosion.
•R410A Refrigerant High Pressure Warning!
The units described in this manual use R410A refrigerant which operates at 50 to 70% higher pressures than
•The refrigerant provided by the manufacturer complies with all the requirements of this system. When using recycled or repro- cessed refrigerant, its quality has to be as good as that of a new refrigerant. It is necessary to have the recycled or reprocessed refrigerant tested by a qualified laboratory. Failure to do so could void the warranty.
•Grounding your ductless system is required!
Follow proper local electrical code on requirements for ground- ing. Failure to follow code could result in death or serious injury.
•Do not use this system if it has been in a flooded area and under- water. Call a licensed HVAC professional to inspect the system and replace controls and electrical components that have been damaged or replace the system, if determined necessary.
•Keep combustible materials at least 3 feet away from either the indoor or outdoor unit.
•Do not insert your hands, tools or any other item into the air intake or air outlet at either the indoor or outdoor unit.
•If outdoor unit is installed on a raised stand, check condition of stand occasionally to ensure its stability.
DUCTLESS SYSTEM DEFFINITIONS
SINGLE SPLIT SYSTEM
A single split system consists of a single outdoor unit and a single indoor unit. The single split system is controlled using a remote control (included with indoor unit).
MULTI-SPLIT SYSTEM
A
EQUIPMENT MODEL NUMBERS
TABLE 1:
OUTDOOR MODEL NUMBER | INDOOR MODEL NUMBER |
LX 16 SEER Single Split Cooling Only Model Numbers | |
DCMF09CSM42Q1 | DCMF09NWM42Q1 |
DCMF12CSM42Q1 | DCMF12NWM42Q1 |
DCMF18CSM42Q1 | DCMF18NWM42Q1 |
DCMF24CSM42Q1 | DCMF24NWM42Q1 |
LX 16 SEER Single Split Heat Pump Model Numbers | |
DHMF09CSM42Q1 | DHMF09NWM42Q1 |
DHMF12CSM42Q1 | DHMF12NWM42Q1 |
DHMF18CSM42Q1 | DHMF18NWM42Q1 |
DHMF24CSM42Q1 | DHMF24NWM42Q1 |
Premium 22 SEER Single Split Cooling Only Model Numbers | |
DCPM09CSM41Q1 | DCPM09NWM41Q1 |
DCPM09CSM42Q1 | DCPM09NWM42Q1 |
DCPM12CSM41Q1 | DCPM12NWM41Q1 |
DCPM12CSM42Q1 | DCPM12NWM42Q1 |
DCPM18CSM42Q1 | DCPM18NWM42Q1 |
DCPM24CSM42Q1 | DCPM24NWM42Q1 |
DCPM36CSM42Q1 | DCPM36NWM42Q1 |
Premium 22 SEER Single Split | Heat Pump Model Numbers |
DHPM09CSM41Q1 | DHPM09NWM41Q1 |
DHPM09CSM42Q1 | DHPM09NWM42Q1 |
DHPM12CSM41Q1 | DHPM12NWM41Q1 |
DHPM12CSM42Q1 | DHPM12NWM42Q1 |
DHPM18CSM42Q1DHPM18NWM42Q1
DHPM24CSM42Q1DHPM24NWM42Q1
DHPM30CSM42Q1DHPM30NWM42Q1
DHPM36CSM42Q1DHPM36NWM42Q1
LX 16 SEER
DHMF18CMM42Q1 | \ |
DHMF24CMM42Q1 | \ |
DHMF30CMM42Q1 | \ |
DHMF36CMM42Q1 | \ |
DHMF42CMM42Q1 | \ |
LX 16 SEER | |
\ | DHPM09NWM42Q1 |
\ | DHPM12NWM42Q1 |
\ | DHPM18NWM42Q1 |
2 | Johnson Controls Unitary Products |