LOW FAN
HIGH FAN
MIDDLE FAN
AUTO
AUTO
COOL
DRY
FAN
HEAT
(Only for cooling and heating units)

898147-UUM-B-0713

REMOTE CONTROL

OPERATION

The wireless remote control gives the home- owner the ability to operate their ductless sys- tem at the touch of a button. The indoor unit and remote control send information back and forth continuously. The remote control must be placed on a table or other surface in direct line of sight with the indoor unit infrared receiver. The remote control should not be placed in a drawer. Make sure that there are no obstruc- tions between the indoor unit receiver and the remote control. Make sure you do not throw nor drop the remote control. The remote should never come in contact with liquids and should not be left in direct contact with the sun or any place that's very hot.

POWER BUTTON

When this button is pressed, the system will turn on. When pressed the second time, the

system will turn off. When turning the system on or off, the Timer and Sleep functions (if activated) will be canceled; however the clock time will be continue to operate even when the system is off.

MODE BUTTON

Press this button to select system operating modes. AUTO mode is the default setting when the system is turn on. As MODE button is pressed,

COOL, DRY, FAN and HEAT (for heat pump only) modes can be selected in this order. The selected mode is displayed on both the remote control and the indoor unit's cover panel displays. When AUTO

mode is selected, the temperature will not be displayed. When in COOL mode, the default setpoint temperature is 77°F (25°C). When in HEAT mode, the default setpoint temperature is 69°F (21°C).

+/- BUTTONS

Use plus (+) and minus (-) buttons to adjust the temperature setting up or down.

NOTICE

The temperature cannot be adjusted when the system is in AUTO mode.

FAN BUTTON

Press FAN button to select fan speed. AUTO fan is the default setting. In AUTO fan mode, the indoor fan speed

is determined by the indoor ambient temperature. Press FAN button to

select the desired fan setting in the following order AUTO, Low Speed, Medium Speed and High Speed. The fan speed selection is displayed at the top of the remote control display by one of these symbols.

NOTICE

The fan speed is not adjustable in DRY mode operation. The low fan speed is necessary to ensure optimal humidity control.

I FEEL BUTTON

Press the I FEEL button to activate the I FEEL feature. When the I FEEL icon appears, the system will satisfy your cooling or heating (heat pump only) setpoint temperatures where the remote control is located. Press the I FEEL button again to deactivate. When I FEEL function is deactivated, the system will satisfy the cooling and heating (heat pump only) setpoint temperatures where the indoor unit is located. To use the I FEEL mode, the remote control must be placed in direct line of sight with the indoor unit infrared receiver. Make sure that there are no obstructions between the indoor unit receiver and the remote control when I FEEL feature is activated.

SWITCH FROM °C TO °F

With system OFF, press MODE and (-) buttons simultaneously to switch from Centigrade to Fahrenheit. The current selection is displayed to the right of the temperature display on the remote control.

CLOCK BUTTON

Press the CLOCK button to adjust the time displayed on the remote

control. The clock icon will flash. Press the (-) and + buttons to adjust the time up or down in one minute increments. Press and hold the button to adjust the time in 10 minute increments. Press the CLOCK button again when correct time is displayed. If no button is pushed for 5 seconds while the display is still flashing, the timer setting will not be saved.

X-FAN BUTTON

Press the X-FAN button once to initiate extended blower operation.

This function allows removal of excess moisture from the indoor unit coil after in order to prevent possible mold or bacterial growth. When the X-FAN function is activated, the indoor fan will continue to run at low speed for 10 minutes after the unit is turned off using the POWER but- ton. The extended fan operation icon is displayed when this feature is turned on. To deactivate, press X-FAN button again and the indoor unit fan will stop running.

LOUVER SETTING BUTTON

Press this button to set the position of the indoor unit swing louver. When this feature

is turned on, icon

appears on the remote

OFF

control display. Continue to press the LOU-

 

VER icon to select the desired swing angle as shown in the following sequence. When activated, the louver will start swinging right to left.

SLEEP BUTTON

Use the SLEEP button to activate or cancel the sleep function. To acti- vate sleep function, press SLEEP button and the sleep icon should appear on the remote control display. Press SLEEP button to cancel sleep function and the sleep icon on the remote control should disap- pear.

In cooling mode, SLEEP function increases temperature by 2°F per hour over a two hour period from the time sleep function is activated. In heating mode, SLEEP function decreases temperature (-2°F per hour) over a two hour period from the time sleep function is activated.

Sleep function is defaulted to off when the system is turned on. If the system is turned off the Sleep function is automatically disabled.

NOTICE

The sleep function is not available in AUTO or FAN modes.

Johnson Controls Unitary Products

5

Page 5
Image 5
Johnson Controls 16, 20 warranty Remote Control Operation