4
GF 600 DV FirelightSpecifications

Input Rates

Natural Gas

40,000 BTU/hr. maximum input
28,600 BTU/hr. minimum input

Propane

40,000 BTU/hr. maximum input
30,900 BTU/hr. minimum input
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa)
Propane: 11.0 WC (2.74 kPa) 13.0 WC (3.23 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.7 WC (.42 kPa) 3.5 WC (.87 kPa)
Propane: 6.4 WC (1.59 kPa) 10.0 WC (2.49 kPa)
Piezo Ignitor / Standing Pilot
Weight: 260 lbs.
29”
(74 cm)
Top Width
24”
(61 cm)
31”
(79 cm)
28 1/2”
(72.5 cm)
Leg Width
27 3/4”
(70.5 cm)
Exhaust
Outlet
Centerline
31 3/4”
(80.5 cm)
Co-Linear
Transition
Adaptor
Height

Co-linear Adapter (Simpson Dura-Vent #923GCL)

dimensions.

16”
(41 cm)
31 1/8”
(79 cm)

Top Exit

Flue

Collar

Height

Suggested Tools for

Installation and Service

External regulator (for Propane only)
Piping which complies with local code
Manual shutoff valve - T-Handle in MA
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10mm open end wrench
1/2”, 7/16” open end wrench or deep socket
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
4 mm allen wrench
• Gloves
Safety glasses
Torx T20 screwdriver
Leak test solution
Reciprocating Saw
Power Drill
THIS FIREPLACE IS SHIPPED FROM THE
FACTORY FOR USE WITH NN
NN
NAA
AA
ATURAL GASTURAL GAS
TURAL GASTURAL GAS
TURAL GAS
ONLY. IF USE WITH PROPANE IS DESIRED,
THE APPLIANCE MUST FIRST BE CON-
VERTED USING THE FUEL CONVERSION KIT
PROVIDED, #154391. CONVERSION SHOULD
BE MADE BEFORE THE APPLIANCE IS IN-
STALLED.