Setting time codes

Time code recording

 

This unit has a built-in time code reader/ generator. It records time codes during recording. It

does not record the user’s bit.

 

Time codes are recorded according to the recording condition as follows:

Time codes are recorded in the REC RUN mode. (REC RUN: time codes run only during

recording.)

 

 

Condition

 

Time code recording

Time code is preset with this unit.

• Time codes preset in the built-in time code generator are re-

 

 

corded. (First time only)

 

 

• When recording ends, the set time codes becomes void and

 

 

regeneration occurs.

 

TOP MENU

 

 

– – – M E N U – – –

S Y S T E M . .

 

 

R E M O T E . .

 

 

A U D I

O / V I

D E O . .

 

T I M E

C O D E . .

 

D I S P L A Y

S E T . .

 

C L O C K A D J U S T . .

 

F A C T O R Y

S E T T I N G

C A N C E L

D R U M

H O U R M E T E R

0 0 0 0 0 0

E X I T

 

 

 

TIME CODE MENU

Time Code

 

Minute Frame

Hour Second

 

– – – T I M E

C O D

E – – –

 

 

 

1.

Display the TOP MENU.

 

 

Remote controller

Main unit

 

Press the MENU button.

Press the EJECT button for at

2.

 

 

least 2 seconds.

Display the TIME CODE menu.

 

Remote controller

Main unit

 

Select the TIME CODE item

Select the TIME CODE item

 

with the / button and

with the PLAY/STOP button

 

press the SET or

button.

and press the PAUSE or FF

3.

 

 

button.

Preset the time code (hour, minute, second and frame).

 

Memo

 

The framing mode is selected from the NDF/DF item of the TIME

 

CODE menu. (NTSC only)

Time code is not preset.

• It reads the time codes recorded on the tape and continues

 

recording time codes from these values. (Regeneration)

If no time code is recorded, it starts from “00”.

*Sometimes, the time codes recorded at the beginning of the tape may not be read.

T C

 

0 0 :

0 0 : 0 0 : 0 0

C L E A R

C A N C E L

N D F / D F ( N T S C )

D R O P

T C

D U P L I C A T E

O F F

 

T C

A D J U S T ( D V )

O F F

 

P A G E B A C K

 

 

 

 

 

Framing mode

 

 

 

(NTSC only)

Resetting the time code to zero:

1Select the CLEAR menu

item.

Remote controller

1Select the TC item with the





button and press the

/

 

SET or

button.

¥The hour digits blink.

2Press the

/

 

button to

shift to the next digit seg-

ment.

 

 

 

3Press the

 

button to

/

 

change the value of the

blinking digits.

 

 

4Repeat steps

2 and 3

above and set all the val-

ues. Press the SET button.

Main unit

1Select the TIME CODE item with the PLAY/STOP button and press the PAUSE or FF button.

2Press the FF or REW but- ton to shift to the next digit segment

3Press the PLAY/STOP but- ton to change the value of the blinking digits.

4Repeat 2 and 3 steps above and set all the values. Press the PAUSE button.

Preset time codes.

2Set the value to EXECUTE and press the SET button

4.

Set the framing mode (NON DROP / DROP) ... (NTSC only)

 

button

DISPLAY

 

SET button

 

 

BARS

STILL

BLANK

MODE

MENU

 

AUDIO

MENU

SEARCH+

MUTING

button

 

 

button

 

OUT SEL.

SET

button

 

SEARCH–

OUT LEV.

 

button

B

SEL.

E

Y/C

 

PLAY button

 

 

EJECT

 

 

EJECT button

 

 

MENIU

REC

PLAY

PAUSE

DVCAM NTSC PAL REC INH.

 

PAUSE button

 

 

CH-1/3

 

SET

REW

STOP

FF

CH-2/4

 

 

BR-DV3000

 

FF button

REW button

 

 

(remote controller) or the PAUSE button (Main unit).

Memo Framing mode (NTSC only) DROP

:Time codes that match the actual time.

NON DROP

: Use this setting if the

 

Remote controller

 

1Select the NDF/DF item

 

with the / button and

 

press the SET or

button.

 

2Press the

 

button to

 

/

 

select the value.

 

 

3Press the SET button to

 

confirm the setting value.

5.

Return to the usual screen.

Main unit

1Select the NDF/DF item with the PLAY/STOP button and press the SET or FF button.

2Press the PLAY/STOP but- ton to select the value.

3Press the PAUSE button to confirm the setting.

STOP button

number of frames is im-

portant.

Remote controller

Main unit

Press the MENU button.

Press the EJECT button.

Memo

When the REC button is held down in the STOP mode, the value of the built-in time code generator is displayed.

Time codes are preset via the TIME CODE menu. It can be set via either the remote controller or the Main unit.

Press the OPERATE button on the Main unit or the remote controller to turn on the power and set the unit to the STOP mode.

*To set it with the main unit, first remove the cassette from the unit if it is loaded.

Recording time codes of a DV input terminal:

Set the TC DUPLICATE item of the TIME CODE menu to AUTO.

To record time codes in the non-drop frame mode from BR-DV600, GY-DV500 or GY-DV700W, set the TC DUPLICATE setting to NON DROP.

Memo

If the REC button is held down in the STOP mode when the TC DUPLICATE item is set to AUTO or NON DROP, the EE signals of the time codes from the DV input terminal can be checked.