JVC BR-DV3000E Backup recording function, Recording using the serial remote terminal, panel to DV

Models: BR-DV3000E

1 38
Download 38 pages 38.34 Kb
Page 22
Image 22
– Backup recording function

RECORDING

Backup recording function

 

By linking this unit to other DV devices, this unit can perform continuous, long-hour recording.

This unit can be set as a backup unit connected to a DV camcorder (GY-DV300/DV500/DV550/

DV5000, etc.). When the recording tape of the source unit ends, this unit can start recording.

This enables long-hour recording.

 

 

 

 

 

 

 

 

 

Backup unit: the main unit

 

 

 

 

OPERATE

 

 

 

EJECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENIU

 

 

 

Mini

A.DUB

REC

PLAY

PAUSE

 

 

 

 

 

DVCAM NTSC PAL REC INH.

 

 

 

DV cable

 

PROFESSIONAL

 

CH-1/3

 

 

 

 

 

 

 

SET

 

 

MIC REMOTE SEL.

INPUT SEL.

REW

STOP

FF

 

 

 

SERIAL

LINE

CH-2/4

 

 

 

DV terminal

DV terminal

9PIN WIRELESS

DV Y/C

BR-DV3000

 

 

 

 

 

 

 

 

 

 

 

INPUT SEL. switch

 

 

RECORDING

Recording using the serial remote terminal

Recording can be turned ON/OFF with the serial remote controller or the footswitch connected

to the SERIAL REMOTE terminal on the rear panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERIAL REMOTE terminal

OPERATE

 

 

 

 

 

EJECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENIU

DV IN/OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mini

A.DUB

 

 

REC

PLAY

PAUSE

AUDIO

LINE

VIDEO

Y/C

 

 

 

 

CH 1/3 CH 2/4

 

 

 

 

 

DVCAM NTSC PAL

REC INH.

 

 

 

 

 

 

IN

 

 

PROFESSIONAL

 

CH-1/3

 

 

 

 

 

 

 

 

REMOTE

 

 

 

 

 

 

SET

 

 

 

 

DC12V

MIC REMOTE SEL.

INPUT SEL.

CH-2/4

 

REW

STOP

FF

 

 

 

OUT

NTSC/PAL

 

SERIAL

LINE

 

 

 

 

 

 

 

 

 

9PIN WIRELESS

DV Y/C

BR-DV3000

 

 

 

 

 

 

 

 

9PINSERIAL NTSC PAL

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE SEL. switch

 

 

 

 

 

 

 

 

 

 

Connection

Connect the DV terminal of the source unit to the

DV terminal of this unit with a DV cable.

Setting up this unit

 Set the INPUT SEL. switch on the front

panel to DV.

 Set the BACKUP REC TIME item of the

SYSTEM (1/2) menu.

Use the following settings according to the length

of the tape of the source unit.

For DV or mini DV cassettes:

25MIN

: 30-minute tape

55MIN

: 60-minute tape

75MIN

: 80-minute tape

115MIN

: 120-minute tape

175MIN

: 180-minute tape

265MIN

: 270-minute tape

OFF

: No backup recording

Set the TC DUPLICATE item of the TIME CODE menu to OFF.

It records the data of the built-in time code

 

generator or the built-in clock.

When the TC DUPLICATE menu item is set to

 

AUTO or NON DROP, the time code of the DV

 

camcorder will stop advancing. If the DV cable

 

is disconnected, the time code of the backup

 

recording will stop advancing.

Operation 1. Recording begins on the source unit.

 

* Please record from the beginning of the re-

2.

cording tape.

This unit begins recording when the

 

tape of the source unit is near the end

 

(about 5 minutes before the end of the

 

tape).

 

• This unit begins recording when the record-

 

ing time of the source unit reaches the time

 

configured by the BACKUP REC TIME set-

 

ting.

Memo

• Backup recording records the video and sound from the source unit to the main unit. While this unit is performing backup recording, please continue shooting from the source unit.

• The audio mode is the mode configured in the source unit. (32k/48k)

• Please set the BACKUP REC TIME item to OFF if the unit is not performing backup recording.

REMOTE (1/2) menu

 

– – – R E M O T E [

1

/ 2

] – – –

 

R E M O T E

 

 

O N

 

L O C A L F U N C T I O N

 

 

A L L

K E Y S

P R E R O L L

 

 

5 S

 

R E M

F F / R E W M O D E

 

F F / R E W

R E M S T O P S E L

 

 

E E

 

P B S T A R T D E L A Y

 

 

O F

 

S Y N C H R O N I Z A T I O N

 

O N

 

N E X T

P A G E

 

 

 

 

P A G E

B A C K

 

 

 

 

Memo

The serial remote control- ler can perform operations other than recording.

The buttons on the unit to be rendered operable can be set via the LOCAL FUNCTION item of the RE- MOTE(1/2) menu.

REMOTE (2/2) menu

 

– – – R E M O T E [

2

/ 2 ] – – –

C O N T R O L L E R S E L

 

T Y P E 1

F O O T

S W

 

O F F

P A G E

B A C K

 

 

• Serial remote controller: RM-G30 • Footswitch

Connection

Connect the serial remote controller (available separately: RM-G30)

or the footswitch to the SERIAL REMOTE terminal on the rear panel.

Setting

 

 Set the REMOTE SEL. switch on the front panel to SE-

RIAL.

 

 Set the REMOTE item of the REMOTE (1/2) menu to

ON.

 

 Set the FOOT SW item of the REMOTE (2/2) menu ac-

cording to the way in which the serial remote terminal

is used.

 

OFF

: Set to OFF when the serial remote controller is used.

L EDGE

The footswitch cannot be used.

: Recording and recording pause operations are

H EDGE

switched at the LOW edge of the footswitch signal.

: Recording and recording pause operations are

L LEVEL

switched at the HIGH edge of the footswitch signal.

: Record at the LOW edge and pause recording at the

 

HIGH edge of the footswitch signal.

Operation

Before using the footswitch, first engage the recording or recording

pause mode via the buttons on the main unit.

Memo

 

• The footswitch can only be used for switching the recording

operation ON/OFF.

• The footswitch functions irrespectively of the REMOTE SEL

switch settings.

40

41

Page 22
Image 22
JVC BR-DV3000E Backup recording function, Recording using the serial remote terminal, Setting up this unit, panel to DV