SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

 

TAn unusual mark appears.

 

• Check the section of the manual

 

 

 

————

that explains LCD monitor/

 

 

 

viewfinder indications

 

 

 

 

 

 

 

 

( pg. 82 – 86).

 

 

 

 

 

 

 

An error indication

• A malfunction of some kind has

• Remove the power supply (battery

 

Y(E01, E02 or E06) appears.

occurred. In this case the

pack, etc.) and wait a few minutes

 

 

 

camcorder’s functions become

for the indication to clear. When it

 

 

 

unusable.

does, you can resume using the

 

 

 

 

camcorder. If the indication

 

 

 

 

remains even though you repeat

 

 

 

 

the above two or three times,

 

 

 

 

please consult your nearest JVC

 

 

 

 

dealer. Do not eject the cassette.

 

 

 

 

This will cause damage to the tape.

 

 

 

 

 

 

 

An error indication

• A malfunction of some kind has

• Eject the cassette once and re-

 

U(E03 or E04) appears.

occurred. In this case the

insert it, then check if the indication

 

 

 

camcorder’s functions become

clears. When it does, you can

 

 

 

unusable.

resume using the camcorder. If the

 

 

 

 

indication remains even though

 

 

 

 

you repeat the above two or three

 

 

 

 

times, please consult your nearest

 

 

 

 

JVC dealer.

 

 

 

 

 

 

 

The charger indicator on

• The temperature of the battery is

• To protect the battery, it is

 

 

the camcorder does not

extremely high/low.

recommended to charge it in

 

Ilight.

• Charging is difficult in places

places with a temperature of 10°C

 

 

 

subject to extremely high/low

to 35°C (50°F to 95°F) ( pg. 75).

 

 

 

temperatures.

 

 

 

 

 

 

 

 

When the image is printed

• This is not a malfunction.

• By recording with “DIS” activated

 

 

from the printer, a black bar

 

( pg. 47) this can be avoided.

 

 

appears at the bottom of

 

 

 

Othe screen.

 

 

 

 

 

 

 

 

 

When the camcorder is

• The DV cable was plugged/

• Turn the camcorder’s power off

 

 

connected via the DV

unplugged with power turned on.

and on again, then operate it.

 

 

connector, the camcorder

 

 

 

Pdoes not operate.

 

 

 

 

 

 

 

 

 

The memory card cannot

 

• Push in the memory card a few

 

 

be removed from the

————

more times ( pg. 14).

 

 

camcorder.

 

 

 

 

 

 

 

Page 73
Image 73
JVC GR-DVL920 Check the section of the manual, That explains LCD monitor, Viewfinder indications, Occurred. In this case