K3 1RU AB Switch Page 4
Alarm Connector
Alarm Connection on each power supply provides status information on the condition of the supply.
9 Pin Dsubminiature
Pin 6 NO Pin 6 shorts to Pin 7 when the Power Supply is Non-Operational
Pin 7 COM
Pin 8 NC Pin 8 shorts to Pin 7 when the Power Supply is Operational
Power Access Panel 1930079
Provides for connection of two
K-16-XPS Power Supplies
Input Power
Nominal : 24VDC
Range : 20 – 30 VDC
Fusing: 2 A Slo-Blo
Physical
DC Input Connector:
Connector: Molex 41995
Mating Connector Kit # 1940164
Mating cable supplied with K-16-XPS
External Power Supplies 1930076
Power Input 100-120/200-240 50-60Hz IEC320 Male.
Power Input cord supplied for North America.
Power Output +24VDC 4.5A, Connector Molex 41995. 3 2 1
6 5 4 1, 2 +24VDC
5, 6 GND
3, 4 N.C.
K3 24VDC External PS Panel
Rear View
PS1 PS2