General
Operation of Connected Camera
When
Switches on the camera that are disabled, as well as disabled menu items are as follows.
Standard connection of
●GAIN
●SHUTTER(1
●WHT.BAL
●FULL AUTO(2
●User 1, 2 and 3 with the following features assigned
BARS
AE LEVEL + AE LEVEL –
NOTE
(1 SHUTTER will also be disabled if the setting is “VARIABLE” or below “1/30” (When Frame rate is 60/24) or “1/25” (When Frame rate is 50).
(2 Setting is configured from
Menu items that are disabled
Menu Page |
| Function | Menu Display on |
| |||
|
|
| |
CAMERA OPERATION | AE LEVEL | REMOTE | |
| SMOOTH TRANS | REMOTE | |
| BARS | REMOTE | |
CAMERA PROCESS [1/2] | MASTER BACK | REMOTE | |
| DETAIL | REMOTE | |
|
| V/H BALANCE | REMOTE |
|
|
|
|
|
| H. FREQUENCY | REMOTE |
|
| SKIN DETECT | REMOTE |
CAMERA PROCESS [2/2] | BLACK | REMOTE | |
| KNEE | REMOTE | |
|
| LEVEL | REMOTE |
| DNR | REMOTE | |
ADVANCED PROCESS | CINEMA | [OFF](3 | |
| GAMMA | [STANDARD](4 | |
|
|
| [CINEMA](4 |
|
|
| [FILMOUT](4 |
|
| LEVEL | REMOTE |
WHITE BALANCE | WHITE PAINT R | REMOTE | |
| WHITE PAINT B | REMOTE | |
GENLOCK | SD H PHASE | REMOTE | |
| HD H PHASE | REMOTE | |
| SC COARSE | REMOTE | |
| SC FINE | REMOTE | |
|
|
|
|
NOTE
(3 CINEMA is forcibly set to “OFF”. To adjust MATRIX, make ues of the menu on the camera.
(4 GAMMA is fixed at the menu setting value of the camera before connecting to the remote control. However, when the menu setting value is OFF, GAMMA will be forcibly set to STANDARD.
30