■Recording onto an MD

English

Recording onto an MD

DISPLAY

MD #8

REMOTE CONTROL RM-RXUV9RMD

 

 

DIMMER

SLEEP

 

 

 

 

 

 

 

STANDBY/ON

DISPLAY

FM MODE TAPE/AUX

 

 

 

AUTO

 

 

 

AHB PRO

PRESET

CD

 

 

PROGRAM RANDOM

REPEAT

 

 

BASS

TREBLE

CANCEL

 

PHONES

 

 

 

 

EDIT

 

CHARA

 

 

/TITLE

 

 

 

 

UP

 

 

 

 

SET

 

 

 

 

DOWN

 

 

 

PTY/EON

 

DISPLAY MODE

 

 

MD

TUNER

CD

CD

#8

 

BAND

 

 

 

 

 

BAND

 

 

 

 

CD

 

 

 

 

 

 

 

 

OPEN/CLOSE

TAPE/AUX

MD TUNER

CD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

 

MULTI CONTROL

 

UP

 

MD

 

 

 

 

EJECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MD REC

 

PTY/EON

DISPLAY

CLOCK

MD REC

MODE

 

 

 

TIMER/

 

 

 

 

 

AHB PRO

VOLUME

 

SNOOZE

MD #´8

MD EJECT 0

7

Track number, Playing time

7

VOLUME

When the System is in use, the display shows oth-

 

 

 

 

MD REC indicator

 

 

 

er items as well.

 

 

 

 

 

For simplicity, we show here only the items de-

Music calendar

 

Track number exceeding

 

 

 

 

 

 

scribed in this section.

 

 

 

 

 

15 is not displayed.

Recording onto an MD from any of the sound sources is simple. Just insert an MD to the Unit, have the source ready, make one or two settings, and you are ready to record. For each source, the procedure is a little bit different so we explain each separately. But first, here are a few things to make your recordings better.

Things To Know Before You Start

Recording —————————————

It may be unlawful to record or play back copyrighted material without the consent of the copyright owner.

Carefully read the “Rules of Digital Dubbing” on page 28.

The MD Recorder supports the following sampling frequencies for digital sources.

For the OPTICAL DIGITAL IN (AUX2): 32 kHz, 44.1 kHz and 48 kHz.

For the CD Player of the Unit: 44.1 kHz.

The recording level, which is the volume at which the new MD is being made, is automatically set correctly, so it is not affected by the VOLUME level of the System. Nor it is affected by ad- justing the sound effects. Thus, during recording you can adjust the sound you are actually listening to without affecting the re- cording level.

Note that it takes 10 seconds until the MD REC button becomes effective after the MD has been inserted.

The accidental erasure prevention knob is provided on the back of an MD cartridge to prevent accidental erasure or recording. It must be set to the close position beforehand.

Recording —————————————Accidental erasure prevention knob

Close Open

For recording or editing

For protecting erasure

When you stick an adhesive label onto the MD cartridge, adhere it securely. If it peels off, ejection trouble, etc. will occur.

To start recording immediately after inserting an MD, it is re- quired to allow several seconds.

Only stereo recording is possible. (Monaural recording that en- ables long recording is impossible.)

Preparation Before Recording ———

Be sure that the MD is not the Play-only type one.

Be sure that the accidental erasure prevention knob of the MD cartridge is set to the close position. Otherwise, “DISC PROTECTED” will appear when you try to record a signal to the MD.

Be sure that the MD has enough space for recording. If not, car- ry out ALL ERASE or ERASE function to erase all the tracks or desired tracks in the MD. (See page 21.) You can check the recordable remaining time of the MD in Stop mode or during re- cording by pressing the DISPLAY button.

(See “Checking the Remaining Time of the MD” mentioned on page 17.)

Standard Recording

You can record any sound source to an MD as follows.

1. Insert an MD with its label side up. 2. Prepare one of the sources.

CD: Use the “CD Synchro Recording” on page 17.

Tuner: Tune in to a station.

AUX1 (LINE IN (AUX1)): Press the TAPE/AUX button on the Unit or the Remote Control until “AUX 1 ANALOG IN” ap- pears on the display.

AUX2 (OPTICAL DIGITAL IN (AUX2)): Press the TAPE/ AUX button on the Unit or the Remote Control until “AUX 2 DIGITAL IN” appears on the display.

3. Play the record source selected in step 2. 4. Press the MD REC button on the Unit.

The MD REC indicator lights up and the selected source is re- corded on the MD.

The track number is incremented by one and it blinks on the music calendar.

MD REC

Source playback Preparation Before Recording ———

When AUX1 or AUX2 is selected as a source, sound synchro recording takes place. The MD Recorder will automatically start recording when a signal is input and stop when no signal continues for more than 30 seconds.

Sound synchro recording may not correctly work if the in- put noise is large, since it starts after detecting the presence of signal.