CONNECTION/INSTALLATION
RM-P2580 System
System with up to 8 cameras
Connecting the control signal cable
(Use a twisted-pair cable for connection. Page 17.)
Camera
Camera 1
MACHINE ID:1 (Menu screen)
RX TERM: OFF Camera
(switch)TK-C1430
Camera 2
MACHINE ID:2 (Menu screen)
RX TERM: OFF (switch)
Camera
Control signal cable
Video signal cable
AC24V
Power or
cable DC12V
AC24V or DC12V
Camera 1 control signal connection terminals
TX+ A
TX B
RX+ C
RX D
Camera 2 control signal connection terminals
TX+ A
A RX +
BRX C TX +
D TX
Connect:
Camera TX+ to
The A B C D marks indicated on both the camera terminals and the
Camera 8
MACHINE ID:8 (Menu screen)
RX TERM: ON (switch)
AC24V or DC12V
•• • • • CAM SW OUT
MONITOR
Time lapse VCR
VIDEO IN
TX B
RX+ C
RX D
Remote Control Unit RM-P2580
TO CAMERA
TO CAMERA
- -
POWER
OFF
ACINPUT
|
|
| CAMERA |
|
|
| ||
|
|
|
| SW | COM |
| ||
|
|
| DATA I / O |
|
|
| ||
|
|
|
| VIDEO INPUT |
|
|
|
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
|
|
|
| MONITOR MONITOR | |
|
|
|
|
|
|
| OUTPUT OUTPUT | |
|
|
|
|
|
|
| 1 | 2 |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
| VIDEO OUTPUT |
|
|
|
|
MONITOR
MONITOR
OUTPUT 2
Setting the switches (
Page 10)
Select the synchronization method of the |
camera image. |
Set the switch on all cameras to LL (Line Lock) |
and match with the V. PHASE. |
( Page 26.) |
MONITOR
OUTPUT 1
This is the connected example of the
When controlling with any system except the
MEMO
| EXT |
| INT/GL |
| DUPLEX |
| RX |
| NOT USED |
VIDEO | IRIS |
DC |
|
ON | Set this switch to the DUPLEX | |
LL | ||
SIMPLEX | * If the setting is changed, be absolutely sure to | |
ON | ||
switch on the power again. | ||
| ||
| Set this switch to ON (signal termination ON) | |
| only on the camera placed at the end of the | |
| control signal cable. | |
| Set to OFF on all other cameras. |
• When operating a system using the |
nected and used on one control signal cable. Consequently, an incorrect switch setting on |
Setting on the MENU screen ( Page 35)
* If the setting is changed, escape from the menu screen once, and definitely switch on the power again.
just a single camera will cause the entire system to work incorrectly. |
• Confirm switch settings on the screen as follows. |
C OMMUN I C A T I O N |
|
S T Y L E | M . DROP |
Set to M.DROP
Set to M.DROP when the
qConfirm that the image from the camera to be checked
is displayed on the monitor.
wTurn OFF and then ON the AC power to the camera to be checked.
eThe camera begins the initial operation and characters similar to those shown in the illustration on the right appear on the monitor screen.
r Confirm that “DUPLEX” and |
MACH I N E I D | 1 |
When connecting
from another machine, make sure that it matches the communication system used.
MACHINE ID setting switches
Set this item to match the
that the ID number is the correct number (the number |
should be the same as the number of the VIDEO IN- |
PUT terminal to which the camera is connected on the rear panel of the
tIf wrong, set the camera ID again.
P R O T O C O L : D U P L E X I D - 0 5
“DUPLEX” should | The number shown in the |
be displayed. | □ □ part of |
| should be correct. |
●Turn OFF the power supply to all equipment to be used before making connections.
●Carefully read the Instructions for each piece of equipment to be used before making connections.
●For the appropriate connection cables and the length of these, carefully read “Connections on the back” on page 16.
●The control signal cable cannot be used for loop connection.
|
|
| ||
|
|