RONTUP
F
1.
Fall prevention wire (not supplied)
Attach from the ceiling slab
3.
Outer case mounting screws
Less than 4 mm
2.
Be sure to loosen the screw.
Mounting
1.Align the position mark of the fastened outer case with that of the camera unit.
NOTE:
When doing so, be careful not to catch the cables in the outer case.
2.Turn the camera unit in the clockwise direction.
T When doing so, ensure that the X mark is visible. (See illustration below)
3.Fasten the camera by tightening the camera fastening screw.
Position mark
1. | 2.T Check |
4.Connect the video signal cable. (A pg. 12)
Lower the protection cover and connect the connectors. Upon connecting, restore the protection cover to cover the connectors.
5.Connect the input power supply cable. (A pg. 12)
6.Wrap insulation tape around cables.
Input power
supply cable
|
|
| 5. |
| 4. |
| Solder or crimp |
|
|
| |
Protection |
| 6. | Insulation tape |
|
| ||
cover |
| Wrap with tape |
Camera fastening screw
3.
Adjusting Images
After mounting is completed, adjust the images while checking the actual image. (A pg. 19 AAdjusting ImagesB)
17