Camera (Interior)
The dome cover, inner dome and outer case are removed.
Procedures for removal. (A pg. 14 AEmbedding the camera to the ceilingB, Step 3. to Step 5.)
V
Lens
(A Next page)
J | U | |
| ||
| T | |
| S | |
| R | |
K | Q | |
| ||
L | P | |
O | ||
M | ||
|
Camera Unit (Rear) | W |
| O |
N
JStrap
A plate to connect the camera unit and the dome cover.
KFastening Screw (x 3)
When embedding the camera in the ceiling, turn this screw to secure the camera. This
screw belongs to a part of the ceiling mount bracket P.
L[MONITOR] terminal (RCA pin) (A pg. 19)
MCamera Unit
NFall Prevention Wire Fastening Hook
OFall Prevention Wire (Supplied) and Wire Mounting Screw
These are the wires and screws connecting the camera unit M and the outer case C. One end of the wire is connected to the hook N securing the safety wire.
PCeiling Mount Bracket (x 3)
This is used as a bracket when embedding the camera to the ceiling. (A pg. 14)
QCamera Fastening Screw
Use this to fasten the camera unit M to the outer case C. To remove (A pg. 14, 16).
R Pan fastening Screw
Ensure to loosen the screw before setting. Further tighten the screw to ensure that camera's shooting direction does not go out of alignment only when it is used in a location with strong vibration. (A pg. 20)
S Imaging Direction mark
Install the camera by aligning the imaging direction with the arrow mark.
T Rotation Knob
Rotate the lens unit to adjust the inclination of the image (to be turned).
U Rotation Center Mark (A pg. 20)
V Tilt Lock screw
Tighten the screw to ensure that camera's shooting direction does not go out of alignment when it is used in a location with strong vibration. (A pg. 20)
W Fall Prevention Wire mounting hole & Screw
(Fall Prevention Wire not included.)
9