INSTALLING THE AIR CONDTIONER
Changing Direction of the Drain Hose
Screw hole
Screw
Drain hose
Drain pan outlet
Rubber cap
<Pour the water in direction of arrow>
Change the direction only when it is necessary.
1Detach the rubber cap with the flyer.
2Detach the drain hose by pulling it and turning to the left.
3Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan.
4Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove.
5Check for leakage on both side of the drain outlet.
CAUTION Make sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.