Fixing the Installation Plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
Right (A)
Left (B)
Underside_right (C)
Rear_right or left (D)
1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.
CAUTION Make sure to drill only one hole after choosing the direction of the pipe.
2Fix the indoor unit.
If you fix the indoor unit on a wall
(1)Fix the installation plate to the wall giving attention to the weight of the indoor unit.
Note If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20mm.
Plastic Anchor
INSTALLING THE AIR CONDTIONER
ENGLISH
Direction of pipe
A B
DD C
(Unit : mm) AQ12, AQ09E/U
Pipe hole (Ø65mm)
27 | 27 |
12068
(Unit : mm) AQ18
Pipe hole (Ø65mm)
27 | 27 |
19068
(Unit : mm) AQ24
Pipe hole (Ø65mm)
<20mm
Wall
34 | 34 |
14068
If you fix the indoor unit on a window frame
(1)Determine the positions of the wooden uprights to be attached to the window frame.
(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3)Attach the installation plate to the wooden upright using tapping screws.
If you fix the indoor unit on a gypsum board
(1)Use stud finder to find out locations of the studs.
(2)Fix the plate hanger on two studs.
CAUTION Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.
CAUTION
Fix the installation plate without incling to one side.
WARNING
Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not strong enough to withstand the product weight, the unit could fall and cause injury.
(Unit : mm) AQ09R
Pipe hole (Ø65mm)
27 | 27 |
140160