Fixing the Indoor Unit in Place
Perform the following work on the area where gas leak test was done priorly.
COMPLETING THE INSTALLATION
ENGLISH
After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate.
1To avoid condensation problems, wrap foam insulation (as shown in the figure A) on a part without insulation on the end of the pipes.
2Wind the pipe, assembly cable and drain hose with vinyl tape.
3Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.
4Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.
CAUTION Make sure pipe does not move when you install the indoor unit on an installation plate.
5Wrap the rest of the pipe with vinyl tape.
6Attach the pipe to the wall using clamps (optional).
<Figure A>
Insulation
Pipes
Installation plate
Vinyl tape | Connecting | |
pipes | ||
|
Connecting wires
Drain hose
Fixing the Outdoor Unit in Place
Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.
If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).
1Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.
2Fix the outdoor unit in level to an appropriate support using anchor bolts.
3If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.
Note Secure the rubber leg to prevent the generation of noise and vibration.
OUTDOOR UNIT INSTALLED ON THE WALL BY RACK
-Ensure the wall will be able to suspend the weight of rack and outdoor unit;
-Install the rack close to the column as much as possible;
-Install proper grommet in order to reduce noise and residual vibration trans- ferred by outdoor unit towards wall.
'X' mm |
| |
'Y' mm |
|
|
Rubber leg |
| |
Model | X | Y |
AQ09R/UA | 457 | 254 |
AQ09E/AQ12 | 538 | 290 |
AQ18 | 543 | 319 |
AQ24 | 660 | 340 |
| Designed to cut off | |
| residual vibration from | |
| outdoor unit to rack. (not | |
| supplied with product) |
Soft rubber designed to cut off vibration from rack to wall.
(not supplied with product)