INSTALLING THE AIR CONDTIONER

ENGLISH

9Connect the cables to the terminals as seen in the picture.

Note Each wire is labeled with the corresponding terminal number.

Indoor unit

 

 

 

09/12/18

 

 

Indoor unit

 

 

 

N(1)

1

2

3

N1N(1)

1

2

3

Outdoor unit

 

 

 

N(1)

1

2

3

N(1)

1

2

3

Outdoor unit

 

 

 

Ground wire (Green/Yellow)

Ground wire (Green/Yellow)

24

Indoor unit

Ground wire (Green/Yellow)

Ground wire

Outdoor unit (Green/Yellow)

CAUTION End of the wire must be circular.

After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.

Screws on terminal block must not be unscrewed with the torque less than 12kgf•cm.

10Connect the grounding conductor to the grounding terminals.

11Close the terminal board cover by tightening the screw carefully.

Note In Russia and Europe, consult with the supply authority to determine the supply system impedance before installation.

WARNING

Connect the wires firmly so that wires can not be pulled out easily. (If they are loose, it could cause burn-out of the wires.)

Connect the wires according to color codes, referring to the wiring diagram.