PREPARING FOR INSTALLATION

Choosing the Installation Location

Indoor Unit

Where airflow is not blocked

Where cool air can be distributed throughout the room

Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram

Wall that prevents vibration and is strong enough to hold the product weight

Out of the direct sunlight

1m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

As far away as possible from the fluorescent and incandescent lights (so that the remote control can be operated well)

A place where the air filter can be replaced easily

CAUTION

Outdoor Unit

Where it is not exposed to strong wind

Well ventilated and dustless places

Out of the direct sunlight and rain

Where neighbors are not annoyed by operation sound or hot air

Solid wall or support that prevents vibration and is strong enough to hold the product weight

Where there is no risk of flammable gas leakage

When installing the unit at a high place be sure to fix the unit legs

3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

Install the unit horizontally

Place where drained water does not become any problem.

Place with no plants (especially climbing plants) and where small animal can not access.

ENGLISH

Avoid the following places to prevent malfunction of the unit

- Where there is machine oil

- Salty environment such as seaside areas

- Where sulfide gas exists

- Other special atmosphere areas

Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.

125mm or more

Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape. Refer to page 19 for further details.

300mm or more

125mm or more

You can select the direction of draining (left or right).

600mm minimum

300mm minimum

600mm minimum

CAUTION:

'L' m as maximum pipe length and 3 m as minimum pipe length (It will reduce noise and vibration)

'L ' meters maximum total pipe length

300mm minimum

'H ' meters maximum total pipe length

Model

L

H

09

15

7

12

15

7

18

15

7

24

20

8

Make at least one round:

It will reduce noise and vibration

The appearance of the unit may be different from the diagram

E-5

depending on the model.

 