INSTALLING THE AIR CONDTIONER
Installing and Connecting the Drain Hose of the Outdoor Unit
ENGLISH
While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following:
1Insert the drain plug into the drain hole on the underside of the outdoor unit.
CAUTION To avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit.
Drain hole
Drain plug
2Connect a drain hose to the drain plug.
3Ensure that condensation draining is adequate.
Bottom surface of outdoor unit
Drain |
|
hole |
|
Drain plug | Drain hose |
CAUTION
In areas with heavy snow fall, piled snow could block the air intake.
To avoid this incident, install a frame that is higher than estimated snow fall. In addition, install a
Estimated |
|
snow fall | Frame |
|
Ground