INSTALLING THE AIR CONDTIONER

Installing and Connecting the Drain Hose of the Outdoor Unit

ENGLISH

While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following:

1Insert the drain plug into the drain hole on the underside of the outdoor unit.

CAUTION To avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit.

Drain hole

Drain plug

2Connect a drain hose to the drain plug.

3Ensure that condensation draining is adequate.

Bottom surface of outdoor unit

Drain

 

hole

 

Drain plug

Drain hose

CAUTION

In areas with heavy snow fall, piled snow could block the air intake.

To avoid this incident, install a frame that is higher than estimated snow fall. In addition, install a snow-proof hood to avoid snow from piling on the outdoor unit.

Snow-proof hood

Estimated

 

snow fall

Frame

 

Ground

E-17

Vivaldi_IM_30271A_E_11.07.09.indd 17

2009-11-7 13:57:11

Page 17
Image 17
Samsung AQ09UGDN, AQ24UGAN manual Installing and Connecting the Drain Hose of the Outdoor Unit