Setting Up the Camera Using an RM-P2580

CAMERA TITLE/ALARM Screen (Continued)

 

Item

 

 

 

 

 

 

 

 

 

Function & Setting

Initial Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM INPUT ..

(Continued)

 

 

POLARITY

Sets the polarity of the alarm signal inputs.

MAKE

 

 

MAKE : Alarm signals are transmitted when point of contact is made.

 

 

 

BREAK : Alarm signals are transmitted when contact is broken.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When an item for the B&W is set to the ALARM 1 to 4, it is set to the MAKE mode even if

 

 

 

 

 

“BREAK” is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DURATION

Sets the length of an alarm operation once an alarm signal has been transmitted.

5s

 

 

(Unit:second)

 

 

 

Setting values : 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s or 60s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

This item is invalid with the system using the RM-P2580. When using the RM-P2580, use

 

 

 

 

 

item “ALARM TIME” instead.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIORITY

Sets whether or not manual operation is accepted in case an alarm input is recog-

ALARM

 

 

nized during manual operation of the camera.

 

 

 

ALARM : Manual operation is not accepted when there is an alarm input.

 

 

 

 

 

 

 

 

 

 

 

(Priority on alarm)

 

 

 

MANUAL : Manual operation is accepted even when there is an alarm input.

 

 

 

 

 

 

 

 

 

 

 

(Priority on manual)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

This item is invalid with a system using the RM-P2580. With this system, the ALARM input

 

 

 

 

 

is permanently given the priority.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM OUTPUT ..

Sets the configuration of the alarm output terminals on the Ceiling Mount.

 

ALARM OUT1

Sets the configuration of the Alarm output 1 terminal.

ALARM

 

 

OFF

: Does not output an alarm signal.

 

 

 

ALARM

: Alarm signal is output upon input of motion detection or an alarm signal.

 

 

 

B&W

: Alarm signal is output when the camera enters the B&W mode.

 

 

 

PRESET : Alarm signal is output when a camera moves to a preset position.

 

 

 

AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This

 

 

 

 

 

 

 

 

 

 

 

is variable depending on the remote control unit in use.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Since the ALARM OUT 1 terminal employs a mechanical relay, its operating sound may

 

 

 

 

 

 

 

 

seem noisy in a quiet environment. In this case, use the ALARM OUT 2 or 3 terminal

 

 

 

 

 

 

 

 

instead.

 

 

 

 

 

 

 

 

 

 

 

Sine the ALARM OUT 1 terminal employs a mechanical relay, the service life of the relay

 

 

 

 

 

 

 

 

may be shortened if signals causing an alarm (motion detect signal, etc.) are applied fre-

 

 

 

 

 

 

 

 

quently. The service life of a relay is 200,000 times of operation. The relay is a consumable

 

 

 

 

 

 

 

 

part and a replacement is chargeable even before the termination of the warranty period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM OUT2

Sets the configuration of the Alarm output 2 terminal.

ALARM

 

 

OFF

: Does not output an alarm signal.

 

 

 

ALARM

: Alarm signal is output upon input of motion detection or an alarm signal.

 

 

 

B&W

: Alarm signal is output when the camera enters the B&W mode.

 

 

 

PRESET : Alarm signal is output when a camera moves to a preset position.

 

 

 

AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This

 

 

 

 

 

 

 

 

 

 

 

is variable depending on the remote control unit in use.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM OUT3

Sets the configuration of the Alarm output 3 terminal.

ALARM

 

 

OFF

: Does not output an alarm signal.

 

 

 

ALARM

: Alarm signal is output upon input of motion detection or an alarm signal.

 

 

 

B&W

: Alarm signal is output when the camera enters the B&W mode.

 

 

 

PRESET : Alarm signal is output when a camera moves to a preset position.

 

 

 

AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This

 

 

 

 

 

 

 

 

 

 

 

is variable depending on the remote control unit in use.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Page 22
Image 22
JVC TK-C676 manual Alarm Input Polarity, Make, Duration, Priority, Alarm Output, Alarm OUT1, Alarm OUT2, Alarm OUT3

TK-C676 specifications

The JVC TK-C676 is a professional-grade CCTV camera renowned for its impressive image quality and reliable performance in various surveillance applications. As part of JVC's reputable line of security products, the TK-C676 incorporates advanced technologies that make it a popular choice among security professionals and businesses alike.

One of the standout features of the TK-C676 is its high-resolution imaging capability. With a 1/3-inch CCD sensor, this camera delivers crisp and clear images, ensuring optimal visibility even in challenging lighting conditions. The camera offers a resolution of 540 TV lines, which allows for detailed surveillance footage that can be crucial for identifying individuals or activities in monitored areas.

Another notable characteristic of the TK-C676 is its robust low-light performance. Thanks to its sense-up technology, the camera can automatically adjust its sensitivity in low-light environments, providing better image quality without the need for external lighting. This feature is particularly valuable for nighttime surveillance or in dimly lit indoor settings, enhancing the overall effectiveness of security measures.

The TK-C676 also excels in flexibility and adaptability with its mechanical IR cut filter. This technology allows for seamless switching between day and night modes, ensuring consistent image quality during both daytime and nighttime operation. This adaptability makes the camera suitable for various applications, including retail stores, parking lots, and public spaces.

Additionally, the JVC TK-C676 features a varifocal lens with a focal length of 3.5mm to 8mm, providing users with the ability to adjust the field of view based on specific surveillance needs. This versatility enables the camera to cover wide areas or focus on particular subjects, making it ideal for both indoor and outdoor placements.

In terms of durability, the TK-C676 is built to withstand harsh environmental conditions. With a sturdy housing that resists both water and dust, this camera can be installed in various locations without compromising on performance. This reliability is essential for continuous operation in demanding environments.

Overall, the JVC TK-C676 is a well-rounded CCTV camera that offers high-resolution imaging, excellent low-light performance, and adaptable features. Its combination of advanced technology, durable construction, and flexible camera options makes it a strong choice for anyone seeking a reliable surveillance solution. Whether for commercial, industrial, or residential applications, the TK-C676 proves to be a valuable asset in enhancing security measures.