![](/images/new-backgrounds/1131382/13138279x1.webp)
Other
Removing a Ceiling Flush Mount Bracket (Optional WB-S575)
3. | <Check the release labels thoroughly before removal.> |
1. Remove the ceiling panel.
Pull the ceiling panel and disengage the two hooks.
2. Remove the camera.
Clamping bracket
Remove the camera from the Ceiling Mount by reversing the at- taching procedure.
☞ P. 16, “Attaching the Camera”
4.
Stoppers
3. Loosen the clamping screws of the Ceiling Flush Mount Bracket.
•Loosen the three clamping screws (by turning them counterclock- wise).
•Make sure that the clamping brackets move inwards.
5.
Release label
6.
*
Push the stopper release lever upwards with a screwdriver, etc.
4. Lower the Ceiling Flush Mount Bracket until the stoppers contact the ceiling plate.
5. Push up the stopper release lever, marked (*) in the figure, using a screwdriver.
•While holding the Ceiling Flush Mount Bracket from below so that it does not drop, push up the one of the three stopper release levers marked (*)using a screwdriver or a similar tool.
•If the ceiling plate is thick and the stoppers cannot be released easily, push up two of the stopper release levers (including the one marked (*)).
6.Pull out the Ceiling Flush Mount Bracket from the hole in the ceiling.
Tilt the Ceiling Flush Mount Bracket and move it obliquely down- ward to remove it.
40