JVC TK-C676 manual Memo

Models: TK-C676

1 44
Download 44 pages 37.37 Kb
Page 9
Image 9

A system that does not employ the RM-P2580 as the controller

MEMO

Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting pieces of non-terminated equipment (cameras or controllers) must be as short as possible. If the length of stub is too long, control precision may suffer.

When the controller is not located at the end of a system.

(An AC 24V power source must be supplied to each camera)

CAM1

 

CONTROL Cable

CAM2 Length of stub

CAM31 Length of stub CAM32

 

Length of stub

PROTOCOL(1)

: ON

MACHINE ID

: 01

RX TERM

: ON

PROTOCOL(1)

: ON

MACHINE ID

: 02

RX TERM

: OFF

CONTROLLER*

PROTOCOL(1)

: ON

MACHINE ID

: 31

RX TERM

: OFF

PROTOCOL(1)

: ON

MACHINE ID

: 32

RX TERM

: ON

Set the TERM switches of the cameras at each end (CAM1 and CAM32) to ON, and the TERM switches of the other cameras to OFF.

Do not terminate at the controller.

VIDEO SWITCHER, etc.

When the controller is located at the end of a system.

(An AC 24V power source must be supplied to each camera)

CONTROL Cable

CAM1

PROTOCOL(1)

: ON

MACHINE ID

: 01

RX TERM

: ON

CAM2 Length of stub

CAM32

Length of stub

Terminate it

with 110

.

 

 

 

 

 

 

CONTROLLER*

PROTOCOL(1) : ON

PROTOCOL(1) : ON

MACHINE ID

: 02

MACHINE ID

: 32

RX TERM

: OFF

RX TERM

: OFF

Set the TERM switch of CAM1 to ON, and terminate at the con- troller with a resistance of 110 .

Set the TERM switches of the other cameras to OFF.

VIDEO SWITCHER, etc.

9

Page 9
Image 9