Connection/Installation
Mounting the Camera
Preparation
Be sure to put on protective glasses to protect your eyes from falling objects when mounting the camera.
1 Make holes on the ceiling
●Use the provided template to make a hole
(R80 mm) for the connection cables to thread behind the ceiling.
●If necessary, also open a screw hole to mount
the ceiling clamping bracket to the ceiling. In this case, align the AD FRONT markB of the template in the direction where the camera faces front and open the screw hole.
2 Pull the cables from the hole in the ceiling
Pull out the fall prevention wire, power cable, coaxial cable, control signal cable, alarm signal cable and provided alarm cable that were mounted to the ceiling slab from the ceiling.
1 | 80 |
| |
Fall Prevention | LAN Cable |
Wire | |
| Power cable |
Alarm signal cable
2
Note:
●Mount the fall prevention wire on a firm place with sufficient strength.
3 Remove the terminal cover
Loosen two screws on the ceiling clamping bracket and remove the terminal cover.
Terminal cover
4 Mount the fall prevention wire that connects the ceiling clamping bracket to the ceiling
6 mm | Fall Prevention Wire |
(15/64 inch) |
|
6 mm and below
R6 mm and below
R4 to 5.5 mm
Caution
●Take note of the length, strength, pull and material (insulation) of the fall prevention wire
and use one with a wire strength of more than 20kg.
●The inner diameter of the ring section of the fall prevention wire mounted on the camera should be R4 mm to R5.5 mm and the outer diameter be R9 mm and below.
●The thickness of the screw head and the fall prevention wire (including the washer) should be 6 mm and below. If it is more than 6 mm, the screw will touch the ceiling and the camera cannot be installed horizontally.
●Use M4 fixing screws.
Memo:
●The wire should be insulated from the ceiling structure. If the ceiling structure is metal and insulation is not provided between the camera and the ceiling structure, image noise may occur.
5Connect the cable (A Page 20 to 23)
Connect cables to the terminal of the ceiling clamping bracket.
The connection cables consist of the alarm signal cable, LAN cable and AC24V power cable.
This connects to AC24V power.
B Alarm input/output signal terminal (A Page 22)
This connects to devices with alarm input/output terminals.
This connects the unit to the network.