SHD-R 3000
English
5.956-486 A2005937 (06/03)

E2

E. Care and maintenance
2. Maintenance schedule
Frequency Type of pump
SHD-R 3000
(F)
Action Procedure By whom?
1, 2, 4, 10
hours after
initial start-
up.
LM
SLA
SSR
Regulate tension in
compression glands See Maintenance Tasks Operator
Once
only after
first 100
operating
hours
all Check tension
of V-belt See Maintenance Tasks Operator
all Oil change See Maintenance Tasks Operator
Weekly
or after
every 40
operating
hours
all Check oil level Oil level must be between MIN
and MAX marks. If level below
MIN, fill up with oil.
Operator
Standard
S / SVA
SLA
SSR
Check oil condition If oil is milky-white, change oil
and tighten piston seal (See
Maintenance Tasks)
Operator
LM Check oil condition If oil has thinned out or is
discoloured, change oil and
tighten piston seal (See
Maintenance Tasks)
Operator
all Check high-pressure
hoses Visual check of high-pressure
hoses for signs of damage such
as
– wear due to abrasion
– inner fabric is visible
– creases due to bending
– porous and split rubber
Replace any damaged hoses
Operator