Cleaning and Maintenance

Continued

LOGS

If you remove logs for cleaning, refer to

Installing Logs and Glowing Embers, page 19, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts, page 31.

Replace ember material periodically as needed. See Replacement Parts, page 31.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather corrosion (rust

spots or streaks and in extreme cases, holes). Have these items replaced im- mediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into vent. Remove any foreign material.

3.Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe sec- tion or fitting has been distributed and loosened. Check mechanical supports such as wall straps for rigidity.

Specifications

(V)CB36N

Maximum Input Rating: 18,000 Btu/hr

Gas Type: Natural

Orifice Size (Main Burner): #45 DMS

(0.082")

Ignition: Millivolt

Manifold Pressure: 3.5" w.c. (0.87 kPa)

Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)

(V)CB36NE

Maximum Input Rating: 18,000 Btu/hr

Gas Type: Natural

Orifice Size (Main Burner): #45 DMS

(0.082")

Ignition: Electronic

Manifold Pressure: 3.5" w.c. (0.87 kPa)

Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)

(V)CB36P

Maximum Input Rating: 18,000 Btu/hr

Gas Type: Propane/LP

Orifice Size (Main Burner): #55 DMS

(0.052")

Ignition: Millivolt

Manifold Pressure: 10" w.c. (2.5 kPa)

Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)

(V)CB36PE

Maximum Input Rating: 18,000 Btu/hr

Gas Type: Propane/LP

Orifice Size (Main Burner): #55 DMS

(0.052")

Ignition: Electronic

Manifold Pressure: 10" w.c. (2.5 kPa)

Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)

All Models

Fireplace Dimension HxWxD (Actual size of firebox measurements do not include nailing flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)

Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)

Service Hints

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP units, propane/LP gas sup- ply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

Technical Services

You may have further questions about installa- tion, operation, or troubleshooting. If so, con- tact DESA Heating, LLC at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating, LLC’s web site at www.desatech.com.