www.desatech.com
117437-01D 25

LOGS

• If you remove logs for cleaning, refer to
Installing Logs and Glowing Embers, page
19, to properly replace logs.
• Use a vacuum cleaner to remove any
carbon.buildup.on.logs.
•. Replace.log(s).if.broken..See.Replacement
Parts,.page.31.
•. Replace.ember.material. periodically. as.
needed..See.Replacement Parts, page 31.

VENTING SYSTEM

Conduct.annual.inspection. of. the. venting.
system.following.these.guidelines:
1.. Check.areas.of.venting. system.that.are.
exposed.to. the. weather. corrosion. (rust.
CLEANING AND MAINTENANCE
Continued
spots or streaks and in extreme cases,
holes)..Have.these. items. replaced. im-
mediately by a qualied service person.
2. Remove the vent cap and shine a ashlight
into.vent..Remove.any.foreign.material.
3.. Check.for. evidence. of. excessive. con-
densation..Continuous.condensation.can.
cause corrosion of caps, pipes and ttings
and.can.be.caused.by.having.excessive.
lateral runs, too many elbows or exterior
portions.of.the.system.being.exposed.to.
cold.weather.
4. Inspect joints to verify that no pipe sec-
tion or tting has been distributed and
loosened..Check.mechanical. supports.
such.as.wall.straps.for.rigidity.
SPECIFICATIONS

(V)CB36N

• Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Natural
• Orifice Size (Main Burner): #45 DMS
(0.082")
•. Ignition:.Millivolt
•. Manifold.Pressure:.3.5".w.c..(0.87.kPa)
•. Min..Inlet.Supply.Pressure:.5.5".w.c..(1.1.kPa)

(V)CB36P

• Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Propane/LP
• Orifice Size (Main Burner): #55 DMS
(0.052")
•. Ignition:.Millivolt
•. Manifold.Pressure:.10".w.c..(2.5.kPa)
•. Min..Inlet.Supply.Pressure:.11".w.c..(2.7.kPa)

(V)CB36NE

• Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Natural
• Orifice Size (Main Burner): #45 DMS
(0.082")
•. Ignition:.Electronic
•. Manifold.Pressure:.3.5".w.c..(0.87.kPa)
•. Min..Inlet.Supply.Pressure:.5.5".w.c..(1.1.kPa)

(V)CB36PE

• Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Propane/LP
• Orifice Size (Main Burner): #55 DMS
(0.052")
•. Ignition:.Electronic
•. Manifold.Pressure:.10".w.c..(2.5.kPa)
•. Min..Inlet.Supply.Pressure:.11".w.c..(2.7.kPa)

ALL MODELS

• Fireplace Dimension HxWxD (Actual size of rebox measurements do not include nailing
anges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)
•. Carton.Dimension.HxWxD:.36.75".x.38".x.16.25".(93.3.x.96.5.x.41.3.cm)
SERVICE HINTS
When Gas Pressure Is Too Low
•. pilot.will.not.stay.lit
•. burners.will.have.delayed.ignition
• heater will not produce specied heat
• for propane/LP units, propane/LP gas sup-
ply.may.be.low
You.may.feel.your.gas.pressure.is.too.low..If.
so, contact your local natural or propane/LP
gas.supplier.
TECHNICAL SERVICES
You.may.have.further.questions.about.installa-
tion, operation, or troubleshooting. If so, con-
tact DESA Heating, LLC at 1-866-672-6040.
When.calling.please. have. your. model. and.
serial.numbers.of.your.heater.ready.
You can also visit DESA Heating, LLC’s web
site.at.www.desatech.com.