www.desatech.com 117437-01D4
3.. If.you.smell.gas
•.shut.off.gas.supply
•.do.not.try.to.light.any.appliance
•.do.not.touch.any.electrical.switch;.do.not.
use.any.phone.in.your.building
•.immediately.call.your.gas.supplier.from.
a.neighbor’s.phone.. Follow. the. gas.
supplier’s.instructions
• if you cannot reach your gas supplier,
call the re department
4. Never install the replace
•.in.a.recreational.vehicle
•.in.windy.or.drafty.areas.where.curtains.
or other combustible (ammable) objects
can make contact with the replace front
• in high trafc areas
5. Do not modify this replace under any
circumstances..Any.parts. removed. for.
servicing.must.be.replaced.prior.to.operat-
ing replace.
6.. Turn.fireplace.off. and. let. cool. before.
servicing, installing or repairing. Only a
qualied service person should install,
service or repair this replace.
7. You must keep control compartments,
burners.and.circulating. air. passages.
clean..More.frequent. cleaning. may. be.
needed.due.to. excessive. lint. and. dust.
from carpeting, bedding material, etc.
Turn.off.the.gas.valve.and.pilot.light.before.
cleaning replace.
SAFETy
Continued
Figure 1 - B-Vent Fireplace
PRODUCT IDENTIFICATION
Top.Louver.Panel
Glass.
Door.
Assembly
Bottom.
Louver.
Panel
Junction.Box.
(Electronic.
Ignition.Only)
Control.
Valve Ember.Tray
Log.Set
Nailing.
Flange
4".B-Vent.
Flue.Collar
8. Have replace and venting system inspect-
ed annually by a qualied service person.
If needed, have venting system cleaned or
repaired..See.Cleaning and Maintenance,
page.24.
9. Do not use this replace to cook food or
burn paper or other objects.
10. Do not use any solid fuels (wood, coal, pa-
per, cardboard, etc.) in this replace. Use
only.gas.type.indicated.on.nameplate.
11. This appliance, when installed, must be
electrically.grounded.in.accordance.with.
local codes or, in the absence of local
codes, with the National Electric Code,
ANSI/NFPA 70, or the Canadian Electric
Code, CSA C22.1.
12. Do not use replace if any part has been
exposed.to.or.under.water.. Immediately.
call a qualied service technician to ar-
range.for.replacement.of.the.unit.
13. Do not operate replace if any log is bro-
ken.or.missing.
14. To prevent performance problems, do
not.use.propane/LP.fuel.tank.of.less.than.
100.lb..(45. kg). capacity. (propane/LP.
units.only).
15..Provide.adequate.clearances.around.air.
openings.
LOCAL CODES
Install and use replace with care. Follow all
local codes. In the absence of local codes,
use.the.la test. edition. of. The National Fuel
Gas Code ANSI Z223.1/NFPA 54* (USA) or
the.current.CSA-B149.1 Installation Code.
(Canada).
*Available.from:
American National Standards Institute, Inc.
1430.Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch.Park
Quincy, MA 02269