Venting Installation
Continued
Checking for Proper Venting
After completing and checking electrical, gas and vent connections, follow lighting instructions and allow main burner to run for approximately 5 minutes. Hold a match or butane lighter flame, near opening between glass and fireplace face and play it along entire length of opening (Smoke may also be used). Proper venting will tend to draw flame or smoke into appliance. Improper venting, escaping or spillage of burned gas, is indi- cated when match flickers or goes out (see Figure 12). Smoke will also tend to disperse away from appliance.
If appliance is not venting properly, shut it off and notify your installer or a qualified service agency to inspect venting system.
Figure 12 - Checking for Spillage
Electrical Supply Connection
CAUTION: Disconnect the electrical power to the supply circuit before attempting to con- nect or service this appliance.
Note: If you do not need to relocate the junc- tion box, to connect the electric supply follow steps 8 through 11 only:
1.Remove 2 screws and outer cover with strain relief bushing on right side of cabi- net (see Figure 13).
2.Remove inner retaining screw on junction box mounting tab.
3.Slide junction box up until screw mounting tab is lined up to notch in outer cabinet.
4.Swing junction box out and slip retaining flange out through slot in outer cabinet.
5.Remove 2 screws and outer cover on left side of outer cabinet.
6.Reinsert junction box retaining flange through slot now on left side and swing screw mounting tab back through notch as before.
7.Slide junction box down till mounting tab holes line up and replace inner retaining screw.
8.With junction box cover removed, pull end of
9.Strip back outer Romex to about 4" and connect black, white and green wires ac- cordingly using 3 wire nut connectors.
10.Tuck tailing wires into junction box and replace junction box cover using 2 remain- ing screws.
11.Tighten adjustment on universal strain bushing to secure Romex sheathing and complete supply connection.
| |||
Cover |
| ||
Cover |
| ||
with Strain | |||
| |||
Relilef |
| with Strain | |
|
| Relief |
A prewired junction box receptacle with strain relief is provided on right side of cabinet for hard wiring unit to a 15 Amp, 120 VAC, 60 Hz grounded branch circuit. If installation demands electrical supply be connected from the left, the entire receptacle box can be relocated to the
Romex Cable
Receptacle
Screw/Tab Retainer
left side by following these instructions:
Figure 13 - Relocating Junction Box Recep-
tacle and Electrical Supply Connection
www.desatech.com | 11 |