4 – Interactive Commands

Selective LUNs Menu (Command Line Option -m)

S

„Auto Configure LUNs

If this option is not available for the selected LUN, the following message appears:

Configuration not permitted. Device(s) either not present or not persistently bound (HBA n)!

4.7.2

Selective LUNs (All HBAs)

7: Selective LUNs 1: All HBAs

When you select this option, SANsurfer FC HBA CLI shows the following options for all HBAs:

„Display LUN Configuration

„Manual Configure LUNs

„Auto Configure LUNs

4.7.2.1

Display LUN Configuration

7: Selective LUNs 1-m: Port Number 1: Display LUN Configuration

When you select the Display LUN Configuration menu, you can choose to show either:

„Details View

„General View

The detailed view shows:

Selective LUN Menu (Display)

HBA Instance

5 (QLA2300 Port 2) : Online

 

WWPN: 21-01-00-E0-8B-25-CB-D8

 

Desc: QLA2302 VA-CPQ (PCI to FC dual channel) HP Appliance

1:

Disk

 

: SEAGATE

 

Vendor

 

Product ID

: ST136403FC

 

Port

Name

: 21-00-00-20-37-1A-6B-CF

 

Port

ID

: 11-01-E4

 

Bind

 

: Yes

2:

Target ID

: 0

Disk

 

: SEAGATE

 

Vendor

 

Product ID

: ST118273 CLAR18

 

Port

Name

: 21-00-00-20-37-11-FF-EF

 

Port

ID

: 11-01-E8

 

Bind

 

: Yes

 

Target ID

: 1

4-50

SN0054614-00 F

Page 102
Image 102
Q-Logic FC HBA CLI manual Selective LUNs All HBAs, Display LUN Configuration, Selective LUNs 1 All HBAs