Q-Logic FC HBA CLI manual Run HBA Diagnostics Loopback Test, Run Read/Write Buffer Test

Models: FC HBA CLI

1 280
Download 280 pages 22.31 Kb
Page 163
Image 163

A

5Non-interactive Commands Command Summary

‰Error – CRC, disparity, or frame length errors occurred.

‰Failed – An error occurred when attempting to issue a command.

‰Loop down – The loop is down.

„CRC – Number of CRC errors.

„Disparity – Number of disparity errors.

„Frame Length – Number of frame length errors.

-kl(<HBA Instance> <HBA WWPN>) [{(<Parameter Name> <Parameter Alias>) <Parameter Value>}]

5.3.17

-kl

(Run HBA Diagnostics Loopback Test)

NOTE:

Under Solaris, this feature is disabled if you are using the driver from the OS installation CDs (QLC driver).

The <Parameter Name>, <Parameter Alias>, and <Parameter Value> options are described in Table 5-8.

The system shows the following information after a loopback test completes:

„Test status

„CRC error

„Disparity error

„Frame length error

5.3.18

-kr

(Run Read/Write Buffer Test)

Use the -krcommand to do read/write buffer test. (To run the loopback test, use the -klcommand—see section 5.3.16.)

To do a read/write test using the default parameters, type:

#scli -kr (<HBA Instance> <HBA WWPN>)

To do a read/write test with customized parameters, type:

#scli -kr (<HBA Instance> <HBA WWPN>) [(-EX -EXCLUDE) <Target WWPN>] (<Parameter Name> <Parameter Alias>) <Parameter Value>

SN0054614-00 F

5-23

Page 163
Image 163
Q-Logic FC HBA CLI manual Run HBA Diagnostics Loopback Test, Run Read/Write Buffer Test