Kenmore 625.3835 manual Manually Initiated Electronic Diagnostics, Resetting To Factory Defaults

Models: 625.3835

1 28
Download 28 pages 18.98 Kb
Page 21
Image 21
MANUALLY INITIATED ELECTRONIC DIAGNOSTICS

MANUALLY INITIATED ELECTRONIC DIAGNOSTICS

1.To enter diagnostics, press the SELECT button and hold for three seconds. The display will change to show turbine count, valve cycle position, and position switch status (open or closed).

Valve Position

Turbine Count

Turbine

Count

(No Water

Indicator

 

 

Flowing)

(Water

Flowing)

 

s

_4

uuu!

 

Im12

WATERFLOW

 

 

 

Position

Switch

Figure 38

Indicator

(Open)

 

TURBINE OPERATION: If no water is flowing through the softener, the turbine indicator displays three zeros. When water is flowing, a 000 to 199 count repeats for each gallon of water passing through the turbine. To check for positive operation of the turbine if zeros are shown, open a nearby soft water faucet and observe the turbine count. If you don't get a reading in the dis- play with faucet open, pull the sensor housing from the valve outlet port (see Fig. 39). Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, unhook the inlet and outlet plumbing and check the turbine for binding.

POSITION SWITCH STATUS: With the valve in service, or any of the recharge cycle positions, the position switch indicator will show the switch open. While the valve is rotating from one position to another, the posi- tion switch indicator will show the switch closed. There is likely a problem if indications vary from this pattern.

OTHER INFORMATION: While in the diagnostics screen, the following information is available and may be beneficial for various reasons. This information is retained by the electronic controller from the first time electrical power is applied to the unit.

Press and hold the /X UP button to display the num- ber of days this controller has had electrical power applied.

Press and hold the V DOWN button to display the number of regenerations initiated by this controller since the model code number was entered.

Motor

 

1

Position

 

Sensor

Switch

j

Housing

 

I

Turbine

 

I

Turbine

 

 

Support

 

 

& Shaft

Valve Outlet

 

 

 

 

Figure 39

NOTE: If the electronic controller is left in the diagnos- tic display (or a flashing display when setting times or hardness), the normal time of day dis-

play automatically returns if a button has not been pressed for 4 minutes. To return to the diagnostic display, repeat step 1, above.

RESETTING TO FACTORY DEFAULTS:

To reset the electronic controller to its factory default for all settings (time, hardness, etc.):

1.Press the SELECT button and hold it until the display changes twice to show the flashing model code.

2.Press the /X UP button to display a flashing "SOS".

Figure 40

3.Press the SELECT button, and the electronic controller will restart.

4.Set the present time, hardness, etc., as described on pages 12 & 13.

Questions? Call the I<enmore Water Line 1-800-426-9345 or visit www.kenmorewater.com