Kenmore 625.3835 manual nEE UFF, O0 MIN, Oomn, C! r, MAXIMUM DAYS BETWEEN REGENERATIONS The

Models: 625.3835

1 28
Download 28 pages 18.98 Kb
Page 17
Image 17
MAXIMUM DAYS BETWEEN REGENERATIONS: The

4. Press SELECT again to display the "Recharge Days"

screen.

RECHARGE

RECHARGE

DAY

_ DAY ]

Default Display

Example:

 

Set to 4 days maximum

 

between regenerations

 

Figure 28

MAXIMUM DAYS BETWEEN REGENERATIONS: The

electronic controller automatically determines regen- eration frequency. This provides the greatest operat- ing efficiency and, under most conditions this feature will be left in its default mode. However, you can set this feature to force a regeneration every set number of days. You may want to do this if, for example, your water supply contains iron and you want the softener to regenerate at least once every few days to keep the resin bed clean. Use the f UP or V DOWN buttons to change the number of days (up to 6).

5.Press SELECT again to display the "97%" screen.

nEE

UFF

RECHARGERECHARGE

Figure 29

97°/o FEATURE: The 97% Feature can save salt and water by regenerating when 97% of the softener's capacity has been used up. With this feature ON, the regeneration can occur at any time (whenever

the system has reached 97% of its capacity). The default is OFF. If this feature is desired, turn it on by pressing the UP f button.

6.Press SELECT again to display the "12 or 24 hr"

screen.

r

AM

C! r

 

 

TIME

Figure 30

12 OR 24 HOUR CLOCK: All time displays are shown in standard clock time (1 to 12 AM; and 1 to 12 PM) at the 12 hr default setting. If 24 hour time format is desired, set to 24 hr by pressing the UP f button.

7.Press SELECT again to display the alternating screens shown in Figure 31.

O0 MIN

a MIN

Bk wshTIME

Bk wshTIME n}

Figure 31

BACKWASH & FAST RINSE TIMES: If you experience salty tasting water after regeneration, you may need to increase the backwash and fast rinse times. The cycle times during regenerations are determined by the softener's electronic controller. However, you may increase the backwash and fast rinse times, in 1 minute increments. If you wish to increase the back- wash time, use the f UP button to add up to 15 min- utes to the backwash time. Then press SELECT to dis- play the alternating screens shown in Figure 32.

w

H I1

U N

OOM'N

RinseTIME

RinseTIME 0}

Figure 32

If you wish to increase the fast rinse time, use the

fUP button to add up to 15 minutes to the fast rinse time.

8.Press SELECT to return to the normal run (time of day) screen.