5Non-interactive Commands Command Summary

Table 5-6. OnError Values

Value

Description

0The error is ignored. This is the default value.

1The test stops on error.

2On error, the data pattern and test repeat until the error is cleared.

5.3.16.6

Run a Loopback Test

The loopback test sends and receives messages, through a loopback or through an echo command, to the switch.

NOTE:

The loopback test is disabled if you are using the drivers from the OS installation.

NOTES:

Run an echo test instead of a loopback test under the following conditions:

„You have a QLA23xx, QLA24xx, QLE23xx, or QLE24xx HBA that is connected to the fabric through a point-to-point connection (F-port).

„The HBA is connected to a switch.

„Your operating system has one of the driver versions listed in Table 5-7.

Table 5-7lists the operating system driver versions that do not require a loopback connector.

.

Table 5-7. Driver Versions Not Requiring a Loopback Connector

Operating System

Driver Version

 

 

Windows XP, Windows 2000, or Windows Server 2003 with SCSI

9.0.0.12

miniport driver

 

Windows Server 2003 with STORport miniport driver

9.0.0.12

Solaris SPARC

4.12

 

 

Table Notes

All subsequent versions also apply.

To do a loopback test using the current parameters, type:

SN0054614-00 F