A

5Non-interactive Commands Command Summary

5.3.15

-i

(Display HBA General Information or VPD Information for One or All HBAs)

To show general HBA information or VPD information for all HBA ports in the system, type the following command:

#scli -i [ <all> ] [ <VPD> ]

Where:

all = All HBAs in the system VPD = Vital Product Data

To show general or VPD information for a specific HBA, type:

#scli -I (<HBA Instance> <HBA WWPN>) [ VPD ]

To show VPD (QLA/QLE24xx only) for all HBA ports in the system, type:

#scli -i VPD

#scli -i all VPD

Where:

all = VPD information for all HBAs in the system

5.3.16

-kl

(Loopback Test)

Use the -klcommand to perform the loopback test.

Use the -krcommand to perform the read/write buffer test (see section 5.3.18.1). To do a loopback test with the default parameters, type:

#scli -kl (<HBA Instance> <HBA WWPN>)

To do a loopback test with customized parameters, type:

#scli -kl (<HBA Instance> <HBA WWPN>) [(<Parameter Name> <Parameter Alias>) <Parameter Value>]

Where:

HBA Instance = HBA number (use -gcommand to find) HBA WWPN = World wide port name of the HBA

-ex or -exclude Target = World wide port name of the target device to be

WWPN excluded from the read/write test

SN0054614-00 F

5-17

Page 157
Image 157