4 – Interactive Commands Diagnostics Menu (Command Line Options -kl, -kr, and -dm)

Table 4-9. HBA Diagnostics Configuration Settings (Continued)

Parameter Name

Alias <param

Value <param value>

Description

<param name>

alias>

 

 

 

 

 

 

 

 

CJTPAT

See table note 1

DataSize

DS

8, 16, 32, 64, 128, 256,

See table note 2

 

 

512, 1024, 2048

 

TestCount

TC

0–65535 (Loopback)

See table note 3

 

 

0–10000 (R/W Buffer)

See table note 3

TestIncrement

TI

1–65535 (Loopback)

See table note 4

 

TI

1–10000 (R/W Buffer)

See table note 4

OnError

OE

0

Ignore

 

 

1

Stop

 

 

2 Loop on error

See table note 5

 

 

 

 

Table Notes:

1.DataPattern is the test pattern in hexadecimal format. Hex Binary

00 00000000

55 01010101

5A 01011010

A5 10100101

AA10101010

FF 11111111

User Defined Pattern (Hex). Random Pattern.

CRPAT - Loopback test only. CSPAT - Loopback test only. CJTPAT - Loopback test only.

2.DataSize specifies the data (frame payload) size in bytes. Actual data that is transferred during any given pass of the test. For R/W buffer test, the maximum data size is 128 bytes.

3.TestCount:

0: Test continuously

1–Max: Total number of tests that will be executed.

4.TestIncrement must be less than the number of test count specified.

5.OnError specifies the action if an error occurs during any given pass.