B – XML Format 2

XML2 Tags for Each Option

S

<Length-9um> "value" </Length-9um> <Length-50um> "value" </Length-50um> <Length-62.5um> "value" </Length-62.5um> <Length-Copper> "value" </Length-Copper> <VendorName>"value"</VendorName> <VendorOUI> "value" </VendorOUI> <VendorPN>"value" </VendorPN> <VendorRev>"value" </VendorRev> <WaveLength>"value" </WaveLength> <CC_BASE> "value" </CC_BASE>

<Options> <SignalLossAsDefinedInSFPMSA> "value"

</SignalLossAsDefinedInSFPMSA>

<SignalLossInvertedFromSFPMSA>"value"

</SignalLossInvertedFromSFPMSA> <TX_Fault_SignalImplemented> "value"

</TX_Fault_SignalImplemented> <TX_DisableImplementedAndDisablesSerialOP>

"value"</TX_DisableImplementedAndDisablesSerialOP> <RATE_SelectImplemented> "value" </RATE_SelectImplemented> </Options>

<BR-Max> "value" </BR-Max> <BR-Min> "value" </BR-Min> <VendorSN>"value" </VendorSN> <DateCode>"value" </DateCode>

<DiagMonitoringType>

<AddressChangeRequired> "value" </AddressChangeRequired> <PowerMeasurement> "value" </PowerMeasurement> <ExternallyCalibrated> "value" </ExternallyCalibrated>

<InternallyCalibrated> "value" </InternallyCalibrated> <DigitalDiagMonitoring> "value" </DigitalDiagMonitoring> <LegacyDiagnostic> "value" </LegacyDiagnostic>

</DiagMonitoringType>

<EnhancedOptions> <SoftRateSelectCtrlAndMonitoring> "value"

</SoftRateSelectCtrlAndMonitoring> <SoftRXLOSMonitoring> "value"</SoftRXLOSMonitoring> <SoftTXFaultMonitoring> "value" </SoftTXFaultMonitoring> <SoftTXDisableCtrlAndMonitoring> "value"

</SoftTXDisableCtrlAndMonitoring> <Alarm-WarningFlags> "value" </Alarm-WarningFlags>

</EnhancedOptions> <SFF-8472-Compliance>"value"</SFF-8472-Compliance> <CC_EXT> 0x7d </CC_EXT>

<VendorSpecific> "value" </VendorSpecific> </Address_A0>

<Address_A2> <TempHighAlarm>"value"</TempHighAlarm> <TempLowAlarm>"value"</TempLowAlarm>

B-6

SN0054614-00 F

Page 210
Image 210
Q-Logic FC HBA CLI manual XML Format XML2 Tags for Each Option