Q-Logic FC HBA CLI manual Resetting to default settings..., done

Models: FC HBA CLI

1 280
Download 280 pages 22.31 Kb
Page 129
Image 129

A

4 – Interactive Commands Statistics Menu (Command Line Options -gs and -ls)

To change the HBA statistics:

1.From the Main Menu, type the number for the Statistics option, and then press ENTER.

2.From the Statistics Menu, type the number for the HBA Statistics option, and then press ENTER.

3.From the HBA Statistics Menu, type the number for the Configuration option, and then press ENTER.

The HBA Statistics Settings Menu contains the following options:

„Current Settings

„Restore Default

„Auto Poll

„Set Rate

„Log to File

4.To see the current port statistics, select Current Settings and then press ENTER. For example:

---------------------------------------

HBA Port Statistics Settings

---------------------------------------

AutoPoll (AP): 10

SetRate (SR): 5

LogToFile (LF): null.csv

5.To restore the HBA defaults, select Restore Default and then press ENTER. The following message appears:

Resetting to default settings..., done.

6.To change the polling, select Auto Poll and then press ENTER. Then select either Auto Poll or Manual Poll and press ENTER to enable that selection.

7.To change the sampling rate, select Set Rate and then press ENTER. You are prompted to enter a rate value between 5 and 30 seconds; the current rate is shown in parentheses. Type a new rate and then press ENTER to update the sampling rate.

8.To save the HBA statistics to a file, select Log to File and then press ENTER. Type the name of a .csv file to save to, and then press ENTER.

Table 4-10shows the values for the HBA port statistics options.

SN0054614-00 F

4-77

Page 129
Image 129
Q-Logic FC HBA CLI manual Resetting to default settings..., done