A

4 – Interactive Commands Diagnostics Menu (Command Line Options -kl, -kr, and -dm)

v1.x.x Build x

Warning: The Diagnostic Loopback and Read/Write Buffer Tests require that the HBA has no outstanding input and output operations. Please make sure there is no active I/O before starting the test(s).

Do you want to proceed with the test(s)?

1:Yes

2:No

Note: 0 to return to Main Menu

Enter Selection: 1

-------------------------------------------------------------------

HBA 1: QEM2462 Port 1 WWPN xx-xx-xx-xx-xx-xx-xx-xxPort ID 02-0E-00

------------------

Test Configuration

------------------

Data Pattern

: Random

 

 

 

Data Size (Bytes)

: 512

 

 

 

Number of test(s)(1-65535)

: 500

 

 

 

Test Increment(1-65535)

: 1

 

 

 

On Error

: Ignore

 

 

 

Test Continuous

: OFF

 

 

 

--------------------------------------------------------------

 

Diagnostics - Loopback Test Result

 

 

 

 

----------------------------------

 

 

 

 

Note: Press <Enter> to stop the test any time

 

 

---------------------------------------------

FrameLength

Active

HBA

Test Data Pattern

Status

CRC

Disparity

---

-----------------------

------

----

---------

-----------

------

1

B4-31-0E-AA-AD-CF-D5-B0

Success

0

0

0

\

4.12.2.2

Run Read/Write Buffer Test

When you select Start Diagnostics Test for the read/write buffer test, the following is returned (example):

------------------------------------------------------------------------------

HBA Instance 4: QLE2562 Port 2 WWPN 21-01-00-1B-32-36-18-EE PortID 01-0F-00

------------------------------------------------------------------------------

------------------

 

Test Configuration

 

------------------

: Random

Data Pattern

Data Size (Bytes)

: 128

Number of test(s)(1-10000)

: 10000

Test Increment(1-10000)

: 1

SN0054614-00 F

4-71

Page 123
Image 123
Q-Logic FC HBA CLI manual Run Read/Write Buffer Test