Q-Logic FC HBA CLI manual Host Topology, Command Line Option -tp -topology

Models: FC HBA CLI

1 280
Download 280 pages 22.31 Kb
Page 55
Image 55

A

4 – Interactive Commands General Information Menu (Command Line Option -g)

„OS version (patches where applicable)

„SDM API version

„A list of HBAs including, for each HBA:

‰HBA model and serial number (SN)

‰Port number

‰WWPN

‰HBA Instance number

‰Status (online/offline)

‰(Repeats for each HBA)

„Total number of QLogic HBAs detected

NOTE:

The SAN Device Management (SDM) API is a QLogic-specific library required for SANsurfer FC HBA CLI. The version number of this library is useful in debugging.

------------------------------------------------------------------------------

Host Name

: BRAGI

2003

Enterprise Ed. x86

OS

Type

: Microsoft Windows Svr

OS

Version

: Service Pack 1 (Build

3790

 

SDM API Uersion

: 1.28.0.50 QLSDM.DLL

 

 

------------------------------------------------------------------------------

HBA Model

QLA2342 (SN C28750):

Port 1

WWPN 21-00-00-E0-8B-01-43-9B SN B05283 (HBA Instance 0) Online

Port 2

WWPN 21-01-00-E0-8B-21-43-9B SN B05283 (HBA Instance 1) Online

HBA Model

QLA2300 (SN D825408):

Port 1

WWPN 21-00-00-E0-8B-05-CB-D8 SN D83179 (HBA Instance 2) Loop down

Port 2

WWPN 21-01-00-E0-8B-25-CB-D8 SN D83179 (HBA Instance 3) Online

HBA Model

QLA2462 (SN FFC0551C34679):

Port 1 WWPN 21-00-00-E0-8B-1F-9D-F0 SN FFC0519U93213 (HBA Instance 4) Online Port 2 WWPN 21-01-00-E0-8B-3F-9D-P0 SN FFC0519U93213 (HBA Instance 5) Loop down

HBA Model QLA21O (SN C655417):

Port 1 WWPN 21—00—00—E0—8B—1A—3F—E0 SN R61343 (HBA Instance 6) Online

-----------------------------------------------------------------------------

Total QLogic HBA(s) : 4

4.1.2

Host Topology

(Command Line Option -tp -topology)

1: General Information 2: Host Topology

SN0054614-00 F

4-3

Page 55
Image 55
Q-Logic FC HBA CLI manual Command Line Option -tp -topology, General Information 2 Host Topology