Procom MN100TBA Specifications, Technical Service, SERVICE HINTS When Gas Pressure Is Too Low

Models: MN100TBA MN060HBA MN100HBA

1 24
Download 24 pages 50.96 Kb
Page 17
Image 17
SPECIFICATIONS

SPECIFICATIONS

Btu(available) Gas Type Ignition

Pressure Regulator setting

Inlet Gas Pressure* (inches of water) Maximum

Minimum

Dimensions, Inches (HxWxD) Heater

Carton

Weight (pounds) Heater Shipping

MN060HBA

MN100HBA

MN100TBA

6,000

6,000/10,000

10,000

Natural Only

Natural Only

Natural Only

Piezo

Piezo

Piezo

3"W.C

3"W.C

3"W.C

10.5"

10.5"

10.5"

4"

4"

4"

19-1/8×14-1/8×6-3/8 19-1/8×14-1/8×6-3/8

19-1/8×14-1/8×6-3/8

22×16-3/4×8-1/8

22×16-3/4×8-1/8

22×16-3/4×8-1/8

12

13

14

15

16

17

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill). * For purposes of input adjustment.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact PRO-COM through the phone num- ber 1-877-886-5989.The information is listed on the front of manual.

SERVICE HINTS

When Gas Pressure Is Too

Low

Pilot will not stay lit

Burner will have delayed ignition Heater will not produce specified

heat

When Gas Quality Is Bad

Pilot will not stay lit

Burner will produce flames and soot

Heater will backfire when lit

You may feel your gas pressure is too low or the gas quality is poor. If

EQUIPMENT SHUTOFF VALVE

For all models. Equipment shutoff valve with 1/8" NPT tap.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the num- ber on the front of this manual. When contacting your dealer or PRO-COM, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

warranty card

Usually, we will ask you to return the defective part to the factory.

so, contact your local natural gas supplier.

ACCESSORIES

Purchase these heater accesso- ries from your local dealer. If they can not supply these accessories, contact PRO-COM for information. You can also write to the address listed on the front of this manual.

FLOOR MOUNTING STAND

Models MN060HBA,MN100HBA, MN100TBA

For locating heater on the floor away from a wall. Complete installation instructions provided with floor mounting stand.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), contact PRP- COM through the phone number 1- 877-886-5989.

1 7

Page 17
Image 17
Procom MN100TBA Specifications, Technical Service, SERVICE HINTS When Gas Pressure Is Too Low, When Gas Quality Is Bad