INSTALLATION

OPERATING YOUR HEATER

CHECKING GAS

CONNECTIONS

WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply

Piping System

Test Pressures In Excess Of

1/2 PSIG (3.5 K Pa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa)

1.Close equipment shutoff valve (see Figure 14).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 15).Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 14).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 15 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 10 and 11 for non-thermostat models or page 12 for thermostat model).Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 11 for non-thermostat models or page 12 for thermostat model).

8.Replace lower front panel.

Figure 14 -Equipment Shutoff Valve

Figure 15 -Checking Gas Joints

WARING:Do not over tighten gas connections.

NON-THERMOSTAT MODEL

nFOR YOUR SAFETYn

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.When lighting the pilot, follow , these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’ s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

1 0

Page 10
Image 10
Procom MN060HBA, MN100HBA, MN100TBA Checking GAS Connections, NON-THERMOSTAT Model, NFOR Your SAFETYn, Read Before Lighting

MN100TBA, MN060HBA, MN100HBA specifications

Procom has made a significant mark in the world of communications technology with its line of radio communication equipment, including the MN060HBA, MN100TBA, and MN100HBA models. These devices are designed to enhance communication capabilities across various sectors, offering advanced features and technologies that cater to both professional and industrial needs.

The Procom MN060HBA is a highly versatile handheld radio that operates within the 6 MHz bandwidth. Known for its robust build quality, the MN060HBA supports multiple frequency ranges, enabling users to communicate across a broad spectrum. It's equipped with a powerful battery that ensures extended operational time, making it suitable for long-term use in demanding environments. Additional features include a user-friendly interface, programmable channels, and encryption capabilities, providing secure communication for mission-critical applications.

Next, the MN100TBA model stands out with its unique tri-band frequency capabilities, allowing seamless communication across different bands. This model is particularly beneficial for users who require flexibility in their communication methods. The MN100TBA incorporates advanced noise-canceling technology, ensuring clear audio even in noisy surroundings. Its rugged design adheres to IP standards, offering resistance against dust and moisture, making it ideal for outdoor operations. Moreover, the device is equipped with a high-resolution display, allowing users to access information and settings quickly.

On the other hand, the MN100HBA is engineered for high-performance applications, featuring dual-band operation that strikes a perfect balance between range and clarity. This model is tailored for professional use, boasting superior audio quality and a comprehensive suite of features, including GPS for location tracking and emergency alerts. The MN100HBA also supports various modulation schemes, delivering flexibility depending on operational needs. With a rechargeable battery and efficient power management system, users can depend on this model for extended periods, even during intensive use.

In summary, Procom’s MN060HBA, MN100TBA, and MN100HBA represent the forefront of radio communication technology. Each model offers unique features tailored to specific user requirements, including durability, multi-band operation, and advanced audio quality. These devices are designed to stand the test of time, offering reliable performance in challenging environments, thereby making them essential tools for professionals in diverse industries.