PREVENTIVE MAINTENANCE

PREVENTIVE MAINTENANCE

Preventive maintenance should be done in daily, weekly, monthly and yearly intervals as necessary. Following preventive maintenance procedures will help keep your MIRACLEAN® Griddle working efficiently. Proper care and servicing will lead to years of quality performance.

PREVENTIVE MAINTENANCE CLEANING

CHART

 

TIME

OPERATOR/OWNER

 

 

FRAME

 

 

 

At Least

Clean MIRACLEAN® Griddle surface.

 

 

Daily

Drain and clean grease drawer.

 

 

 

Completely wipe down MIRACLEAN®

 

 

 

Griddle cabinet.

 

 

At Least

Check MIRACLEAN® Griddle surface

 

 

Monthly*

to insure proper maintenance.

 

 

 

(Review proper cooking procedures.)

 

 

 

Check calibration of thermostats.

 

 

 

Review operating instructions

 

 

 

received with MIRACLEAN® griddle.

 

 

Every

Clean gas valve vent tube.

 

 

6 Months*

Check burner manifold pressure.

 

 

At Least

QUALIFIED SERVICE PERSONNEL ONLY

 

 

Yearly*

Have MIRACLEAN® griddle completely

 

 

 

checked, calibrated, tested, cleaned, etc.

 

 

 

by qualified service personnel. Be sure to

 

 

 

check color and height of pilot flame.

 

 

 

 

 

*High production facilities should be checked more often. Contact the factory or a local service company to perform maintenance and repairs.

AVOID SERVICE CHECKLIST

Before calling for service, review this list. It may save you both time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.

 

PROBLEM

 

SOLUTION

 

 

 

 

 

Miraclean® Griddle

 

• Is the gas connected?

 

 

does not operate:

 

• Is the gas supply turned on?

 

 

 

 

• Is the gas valve knob in the ON

 

 

 

 

position?

 

 

 

 

• Is the pilot lit?

 

 

 

 

• Is the switch turned on?

 

 

 

 

• Is the thermostat set at the desired

 

 

 

 

position?

 

 

 

 

 

 

THERMOSTAT CALIBRATION

Calibration is not covered under warranty.

Tools: Accurate surface thermometer

Standard screwdriver

1.Turn the exhaust system ON.

2.Turn on the griddle with thermostat set at 300°F. Allow burners to cycle on and off three times. (Approximately 60 minutes.)

3.Place accurate thermometer on surface over thermostat bulb. Use the inverted “V” on the front of the griddle plate to locate thermostat bulb. Place the surface thermometer about half waytoward the back of the plate.

4.When burners cycle off, the griddle is up to temperature. If temperature is within 25°F of thermostat setting, remove knob. Loosen four screws in the thermostat dial plate. Replace knob. Reset the dial plate to match the thermometer reading.

Thermostat calibration

Thermostat knob removed to reveal calibration screws.

5.Remove the knob to tighten screws on dial plate and replace the knob.

For calibration over a 50°F difference, contact a qualified service company.

CONDITIONING THE

MIRACLEAN® GRIDDLE PLATE

The Miraclean® Griddle plate has been “seasoned” at the factory. The Miraclean® surface when heated creates a thin layer of chrome oxide which acts as a releasing agent for food product. You may feel that you need to recondition your griddle surface.

1.Follow cleaning instructions on page 5.

2.Heat the MIRACLEAN® to 400°F for one hour.

3.Lower thermostat to 350°F, allowing the MIRACLEAN® to cool to about 350°F, as is evident when griddle cycles on or surface thermometer indicates correct temperature.

4.Lightly coat the MIRACLEAN® surface with griddle oil.

NOTE: Despite the food releasing properties, the chrome surface is not a true “non-stick” surface. For best cooking results and product appearance, use griddle oil for products that require the surface to be conditioned.

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation. In the event that your Miraclean® Griddle, under warranty, needs repairs other than routine cleaning, you are requested to contact KEATING OF CHICAGO, INC. (1-800 KEATING).

PARTS ORDERING

Parts may be ordered by part number by calling Keating at 1- 800-KEATING or your service company. You may also order on-line at Keating’s part store, www.keatingofchicago.com.

Refer to the Keating MIRACLEAN® Griddle Limited Warranty for complete service and ordering information.

The model/serial plate is located inside the cabinet. Remove grease drawer. The model and serial numbers are necessary when ordering.

7

Page 9
Image 9
Keating Of Chicago Preventive Maintenance, Avoid Service Checklist, Conditioning The Miraclean Griddle Plate, Time