PERFORMANCE DATA SHEET

Base Grille Water Filtration System

Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of

Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of

Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,

 

 

 

 

 

 

 

 

 

 

 

 

 

Tetrachloroethylene,

Endrin, Alachlor,

Chlorobenzene,

Ethylbenzene, TI-HM, MTBE and VOC.

 

 

 

 

 

 

This

system

has

been

tested

according

 

to

NSF/ANSl

Standards

42 and

53 for the

reduction

of the

substances

listed

below.

The

 

 

 

concentration

of the

indicated

substances

in water entering

the

system was

reduced

to

a concentration

less than or equal to the

 

 

 

permissible

limit

for

water

leaving

the

system,

as specified in NSF/ANSl Standards 42 and 53.

 

 

 

 

 

 

 

 

 

 

 

 

 

Substance

Reduction

NSF Reduction

 

Average

 

 

Influent

Challenge

 

 

Maximum

 

Average

Minimum

%

Average

%

 

Aesthetic

Effects

 

 

Requirements

 

Influent

 

 

 

Concentration

 

 

 

Effluent

 

Effluent

Reduction

 

Reduction

 

Chlorine

 

Taste/Odor

 

 

50%

 

reduction

 

2.0

mg/L

 

 

2.0 mg/L _+10%

 

 

 

0.08

mg/L

 

2.0

 

mg/L

95.93

 

 

97.36

 

 

Particulate

Class

I*

 

 

85%

 

reduction

 

3533333#/mL

 

At

east 10,000

part

c es/mL

22000

#/mL**

11567

#/mL

99.38

 

 

99.67

 

 

Contaminant

 

 

 

 

NSF Reduction

 

Average

 

 

Influent

Challenge

 

 

Maximum

 

Average

Minimum

%

Average

%

 

Reduction

 

 

 

 

 

Requirements

 

Influent

 

 

 

Concentration

 

 

 

Effluent

 

Effluent

Reduction

 

Reduction

 

Lead: @ pH

6.5

 

 

 

0.010

rng/L

 

 

150 ug/L

 

 

0.15

mg/L

_+10%

 

 

1.0 ug/L

 

1 ug/L

 

99.33

 

 

99.33

 

 

Lead: @ pH

8.5

 

 

 

0.010

mg/L

 

 

157 ug/L

 

 

0.15

mg/L

_+10%

 

 

2.0 ug/L

 

1.08

ug/L

98.72

 

 

99.31

 

 

Mercury:

 

@ pH 6.5

 

 

0.002

mg/L

 

 

0.0058

mg/L

 

0.006

mg/L

_+10%

 

 

0.0002

mg/L

0.0002

mg/L

96.53

 

 

96.53

 

 

Mercury:

 

@ pH 8.5

 

 

0.002

mg/L

 

 

0.0057

mg/L

 

0.006

mg/L

_+10%

 

 

0.0002

mg/L

0.0002

mg/L

96.5

 

 

96.5

 

 

 

Benzene

 

 

 

 

 

 

 

0.005

mg/L

 

 

15 ug/L

 

 

 

0.015

mg/L

_+10%

 

 

0.5 ug/L

 

0.5

 

ug/L

96.67

 

 

96.67

 

 

O-Dichlorobenzene

 

 

0.6 mg/L

 

 

 

1750 ug/L

 

 

1.8 _+10%

 

 

 

 

1.0 ug/L

 

1.0

 

ug/L

99.94

 

 

99.94

 

 

Toxaphene

 

 

 

 

 

0.003

mg/L

 

 

15 ug/L

 

 

 

0.015

_+10%

 

 

 

1.0 ug/L

 

1.0 ug/L

93.33

 

 

93.33

 

 

Atrazine

 

 

 

 

 

 

 

0.003

mg/L

 

 

10 ug/L

 

 

 

0.009

mg/L

_+10%

 

 

2 ug/L

 

 

2 ug/L

 

80.8

 

 

80.8

 

 

 

Asbestos

 

 

 

 

 

 

99%

 

 

 

 

 

101 MFL

 

 

107to

108fibers/L tt

 

 

0.17

MFL

 

0.17

MFL

99.83

 

 

99.83

 

 

Live

Cysts _

 

 

 

 

>99.95%

 

 

 

120,000/L

 

 

50,000/L

min.

 

 

 

8/12

 

 

 

1/L _

 

99.99

 

 

>99.99

 

 

Turbidity

 

 

 

 

 

 

 

0.5 NTU

 

 

 

11.4 NTU

 

 

11 _+1 NTU

 

 

 

0.41

NTU

 

0.24

NTU

96.4

 

 

97.89

 

 

Alachlor

 

 

 

 

 

 

 

0.002

mg/L

 

 

41.3

ug/L

 

 

0.04

_+10%

 

 

 

0.2 ug/L

 

0.2 ug/L

99.52

 

 

99.52

 

 

Endrin

 

 

 

 

 

 

 

0.002

mg/L

 

 

5.9

ug/L

 

 

0.006

_+10%

 

 

 

0.5 ug/L

 

0.3

 

ug/L

91.5

 

 

95.47

 

 

Ethylbenzene

 

 

 

 

0.7 mg/L

 

 

 

1867 ug/L

 

 

2.1 _+10%

 

 

 

 

0.70

ug/L

 

0.0588

ug/L

99.96

 

 

100

 

 

 

Lindane

 

 

 

 

 

 

 

0.002

mg/L

 

 

1.9

ug/L

 

 

0.002

_+10%

 

 

 

0.02

ug/L

 

0.02

ug/L

98.93

 

 

98.93

 

 

Chlorobenzene

 

 

 

0.6 mg/L

 

 

 

2.0

ug/L

 

 

2.0 _+10%

 

 

 

 

0.0005

ug/L

0.0005

ug/L

99.98

 

 

99.98

 

 

Tetrachloroethylene

 

 

0.005

mg/L

 

 

14.2 ug/L

 

 

0.015

_+10%

 

 

 

0.5 ug/L

 

0.5

 

ug/L

96.47

 

 

96.47

 

 

TTHM

 

 

 

 

 

 

 

0.080

mg/L

 

 

465

ug/L

 

 

0.45

_+20%

 

 

 

1.0 ug/L

 

0.5

 

ug/L

99.78

 

 

99.88

 

 

MTBE

 

 

 

 

 

 

 

0.005

mg/L

 

 

14 ug/L

 

 

 

0.015

_+20%

 

 

 

0.70

ug/L

 

0.52

ug/L

94.94

 

 

96.27

 

 

VOC

 

 

 

 

 

 

 

 

0.015

mg/L

 

 

0.3520

mg/L

 

0.300

_+10%

 

 

 

0.0060

mg/L

0.0008

mg/L

98.4

 

 

99.78

 

Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).

 

 

 

 

 

 

 

Temp.

= 68°F

to

71.6°F

(20°C

to 22°C).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It is

essential

that

operational,

maintenance,

and

filter

 

 

 

 

 

Do not use with water

that

is microbiologically

 

unsafe

or

of

 

 

replacement

requirements

 

be carried

out for

the product

to

 

 

 

unknown

quality

without

adequate

disinfection

before

or

after

the

 

perform

as advertised.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system.

Systems

certified

 

for

cyst

reduction

may

be

used on

 

Model

T1KB1 : The

filter

monitor

system

measures

the amount

of

 

disinfected waters that may contain filterable cysts.

 

 

 

Refer to the front cover or

"Accessories"

section

for

the

 

 

 

water

that

passes

through

 

the

filter

and

alerts

you

to

replace

the

 

 

 

 

filter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manufacturer's name, address and telephone number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Style

 

1 -

When

the

filter

indicator

reads

10%,

order a

new

filter.

 

Refer

to the

"Warranty"

section for

the

Manufacturer's

limited

 

 

When

the

filter

indicator

 

reads

0%,

it is

recommended

that

you

 

 

warranty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace

the filter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Style

 

2 -

When

the

filter

indicator

light

changes

from

green

to

 

 

 

 

Application

 

Guidelines/Water

Supply

Parameters

 

 

 

yellow, order a new filter. When the filter indicator light changes

 

Water

Supply

 

 

 

 

 

 

 

City

or Well

 

 

 

 

 

 

 

from

yellow

to

red, it is recommended

 

that you

replace the filter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use

replacement

 

cartridge

T1RFKB1,

 

part

#9030.

In Canada,

use

Water

Pressure

 

 

 

 

 

 

30 - 120

psi

(207 - 827 kPa)

 

 

replacement

cartridge

T1 RFKB1,

part

#9030B.

2007

suggested

 

Water

Temperature

 

 

 

 

 

33 ° - 100°F (0.6 ° - 37.8°C)

 

 

 

retail

 

price of $41.99

U.S.A./S51.99

 

Canada. Prices are subject to

Service

Flow

Rate

 

 

 

 

0.5

gpm

(1.9

L/min) @ 60 psi

 

 

change

without

notice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

The product is for cold water use only.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. t+Fibers greater than 10 um in length

_Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

24

Page 24
Image 24
Kenmore 10656836603, 106.57022601, 10656834603 Performance Data Sheet, Model TIKB1/TIRFKB1 Capacity 100 Gallons 379 Liters