PRODUCT DATA SHEETS
Base Grille Water Filtration System Model
42 for the reduction of Chlorine (Class I) Taste and Odor and against
(_)Tested and certified by NSF International against ANSI/NSF Standard ANS/NSF Standard 53 for the reduct on of Lead, Cysts and Turb d ty.
Capacity; 250 Gallons (946 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance | Reduction | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | ||
Aesthetic | Effects | MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | ||
Chlorine Taste/Odor | N/A |
| 1.9 mg/L | N/A | 0.04 mg/L | N/A |
| 97.9% |
| 994707 | ||
Particulate |
| N/A |
| 610,000/mL* | N/A | 154/mL | N/A |
| 99.97% |
| 994711 | |
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | |||
Reduction |
| MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | ||
Cyst |
| 99.95%** | 89,250/mL* | 6/mL | 2.3/mL |
| 99.993% |
| 99.997% |
| 994710 | |
Turbidity |
| 0.5 NTU | 29 NTU | 0.1 NTU | 0.09 NTU | 99.5% |
| 99.69% |
| 994710 | ||
Lead: @pH 65 | 0.015 | mg/L | 0.16 mg/L*** | 0.001mg/L | 0.001 | mg/L | 99.4% |
| 99.4% |
| 994708 | |
Lead: @pH 8.5 | 0.015 | mg/L | 0.16 rag/L*** | 0.002 mg/L | 0.001 | mg/L | 98.8% |
| 99.4% |
| 994709 |
Base Grille Water Filtration System Model
42 for the reduction of Chlorine (Class I) Taste and Odor and against
(_)Tested and certified by NSF International against ANSI/NSF Standard ANS/NSF Standard 53 for the reduct on of Lead, Cysts and Turb d ty.
Capacity; 400 Gallons (1514 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance | Reduction | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | ||
Aesthetic | Effects | MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | ||
Chlorine Taste/Odor | N/A |
| 2.0 mg/L | N/A | 0.04 mg/L | N/A |
| 98% |
| 994707 | ||
Particulate |
| N/A |
| 610,000/mL* | N/A | 154/mL | N/A |
| 99% |
| 994711 | |
Contaminant | U.S. EPA | Average | Maximum | Average | Minimum | % | Average | % | NSF Test | |||
Reduction |
| MCL |
| Influent | Effluent | Effluent | Reduction |
| Reduction | Number | ||
Cyst |
| 99.95%** | 89,250/mL* | 6/mL | 2.3/mL |
| 99.993% |
| 99.997% |
| 994710 | |
Turbidity |
| 0.5 NTU | 29 NTU | 0.12 NTU | 0.09 NTU | 99.59% |
| 99.69% |
| 994710 | ||
Lead: @pH 65 | 0.015 | mg/L | 0.16 mg/L*** | 0.001mg/L | 0.001 | mg/L | 99.4% |
| 99.4% |
| 994708 | |
Lead: @pH 8.5 | 0.015 | mg/L | 0.16 rag/L*** | 0.002 mg/L | 0.001 | mg/L | 98.8% |
| 99.4% |
| 994709 |
•It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
•Model
•Model
part# 9902. 2002 suggested retail price of $39.95 U.S.A./ $49.95 Canada. Prices are subject to change without notice.
•The product is for cold water use only.
•Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or a_er the system.
•Refer to the front cover or "Assistance or Service" section for the Manufacturer's name, address and telephone number.
•Refer to the "Warranty" section for the Manufacturer's limited warranty.
| Application | Guidelines/Water | Supply Parameters |
Water | Supply |
| City or Well |
Water | Pressure | 30 | - 120 psi (207 - 827 kPa) |
*Test requirement is at least t00,000 particles/ml of AC Fine Test Dust.
**Cyst performance is % reduction based on NSF Standard 53.
***Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®NSF is a registered trademark of NSF International