Kenmore 110.9656 Gas supply connection requirements, Gas supply line, Option 1 Recommended method

Models: 110.9656

1 48
Download 48 pages 2.13 Kb
Page 8
Image 8

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve,

Securely tighten all gas connections.

if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column,

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to de so can result in death, explosion, or fire.

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your local Sears store or Sears Service Center.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different

gas without consulting your gas company.

Gas supply line

r/2" IPS pipe is recommended.

%" approved tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

Must include y8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).

Must include a shutoff valve:

An individual shutoff valve must be installed within 6 feet

(1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

AC E

ililli

BD

A. %" flexible gas connector

B. _" pipe to flare adapter fitting

C. _" NPT minimum plugged tapping

D._2"NPT gas supply line E.Gas shutoff valve

Gas supply connection requirements

For close clearances, a %" to %" elbow is recommended to prevent kinking of the gas line.

Use only pipe-joint compound. Do not use TEFLON _t tape.

There are many methods by which your gas dryer can be connected to the gas supply. Listed here are some guidelines for two different methods of connection.

Option 1 (Recommended method)

Flexible stainless steel gas connector:

If local codes permit, use a new flexible stainless steel gas connector (Design Certified by CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a %" flare x %" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.

Option 2 (Alternate method)

Approved aluminum or copper tubing:

Lengths under 20 ft (6.1 m) can use %" approved tubing (if codes and gas supplier permit).

If you are using Natural gas, do not use copper tubing.

%" flare x %" NPT adapter fitting between dryer pipe and %" approved tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, %" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger tubing.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON °t tape.

t®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Page 8
Image 8