5.Place the inner door assembly inside the outer door assembly. To fit correctly, the inner door assembly edge fits completely inside the outer door assembly edge.
6.Reassemble the inner and outer door assemblies with the 6 screws.
Reverse the strike
1.Use a small
2.Remove the strike.
3.Insert strike and plug strip on the opposite side.
A. Plug strip (cannot be seen from this angle)
B. Door strike
Reinstall the door
1.Reattach door to dryer front panel with the 4 screws.
®
A. Dryer front panel
B. Door assembly
2.Check for fingerprints on the glass. Clean glass if necessary.
3.Close door and check that it latches securely.
1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2.Check that you have all of your tools.
3.Dispose of/recycle all packaging materials.
4.Check the dryer'sfinal location. Be sure the vent is not crushed or kinked.
5.Check that the dryer is level. See "Level Dryer."
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord,
Failure to follow these instructions can result in death, fire, or electrical shock.
6.Plug into a grounded 3 prong outlet. Turn on power.
7.Remove any protective film or tape remaining on the dryer.
8.Read "Dryer Use."
9.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.
10.Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only modifier.
If the dryer will not start, check the following:
•Dryer is plugged into a grounded 3 prong outlet.
•Electrical supply is connected.
•Household fuse is intact and tight, or circuit breaker has not tripped.
•Dryer door is closed.
1f. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check to see that the gas supply line shutoff valve is open.
•If the gas supply line shutoff valve is closed, open it, then repeat the
•If the gas supply line shutoff valve is open, contact a qualified technician.
14