Alevelfloorwithamaximumslopeof1"(2.5cm)underentire

dryer(Ifslopeisgreaterthan1"[2..5cm],installExtended DryerFeetKit,PartNo.279810Clothesmaynottumble.) properlyandautomaticsensorcyclesmaynotoperate correctlyifdryerisnotlevel.

Foragarageinstallation,youwillneedtoplacethedryerat

least18"(46cm)abovethefloorIfusingapedestal,youwill.

need18"(46cm)tothebottomofthedryer.

Donotoperateyourdryerattemperaturesbelow45°F(7°C)At. lowertemperatures,thedryermightnotshutoffattheendofan

automaticcycleDryingtimescanbeextended..

Thedryermustnotbeinstalledorstoredinanareawhereitwill beexposedtowaterand/orweather.

CheckcoderequirementsSomecodeslimit,ordonotpermit,.

installationofthedryeringarages,closets,mobilehomesor

Custom undercounter installation - Dryer only

2" •

_

 

36" rnin

 

 

'%1I IJ

 

1"* _

_ 27"---tb-_--

1"*

2 5 crn

(68.6 crn)

{2.5 cm)

*Additional spacing recommended

Closet installation - Dryer only

I1t L J ,..m0xI.-.

_3"

(7.6crn)

sleepingquartersContactyourlocalbuildinginspector..

NOTE:Nootherfuel-burningappliancecanbeinstalledthe sameclosetasadryer.

Installation clearances

. f,6 ,oI

-NN

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

50"

(128.27 cm)

/

36"

(91.4 cm)

!

!

*28.65"

(72.77 cm)

27"

(68.6 cm)

*Most installations require a minimum 51/2''(14 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements."

BI_Itll

I I

24in.2

11"_ 28.6s"_o"*1

7

(2.5cm) (72.77cm)

(Ocm)

 

A

 

B

A. Side view - closet or confined area

B. Closet door with vents

*Side or bottom venting - additional spacing recommended

Recessed or closet installation - Dryer on pedestal

Minimum installation spacing for recessed area, custom undercounter or closet installation

The following dimensions shown are for the minimum spacing allowed.

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing of 1" (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

A. Recessed area

B. Side view - closet or confined area

*Additional spacing recommended

**Side or bottom venting - additional spacing recommended

Page 6
Image 6
Kenmore 110.9656 manual Installation clearances, Custom undercounter installation Dryer only