Kenmore 153.32116, 153.32118 Condensate Drain Line Installation, T & P Valve and Pipe Insulation

Models: 153.32116 153.32118

1 28
Download 28 pages 36.51 Kb
Page 11
Image 11
Property Damage Hazard

8.After piping has been properly connected to the water heater, open the nearest hot water faucet. Then open the cold water shut off valve and allow the tank to completely fill with water. To purge the lines of any excess air and

sediment, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet

and check all connections for leaks.

Please note the following:

The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, or polybutylene. This water heater must not be installed using iron piping or PVC water piping.

Use only pumps, valves, or fittings that are compatible with potable water.

Use only full flow ball or gate valves. The use of valves that may cause excessive restriction to water flow is not recommended.

Use only 95/5 tin-antimony or other equivalent solder. Any lead based solder must not be used.

Piping that has been treated with chromates, boiler seal, or other chemicals must not be used.

Chemicals that may contaminate the potable water supply must not be added to the piping system.

Property Damage Hazard

Avoid water heater damage.

Install thermal expansion tank if necessary.

Do not apply heat to cold water inlet.

Contact qualified installer or service agency.

Condensate Drain Line Installation

Install two 1/2" PVC discharge lines from the condensate drains (located on the right side near the back). The lines should terminate a maximum of six inches above an adequate drain. Do not discharge the condensate drain lines into the metal drain pan. If no floor drain is available or the drain is above the level of the condensate line, a condensate pump should be installed. These pumps are available from local distributors.

When installing the drain line, note the following:

Plastic pipe or tubing must be used to connect the condensate drain to a suitable drain or condensate pump.

Condensate drain lines should be installed in conditioned areas only. Install approved insulation on the condensate drain lines to prevent condensation from forming on the outside of the drain lines. Condensation drain lines installed in areas that are subject to freezing temperatures should be wrapped with a nationally recognized/listed heat tape. Install per manufacturer's instructions.

Do not connect condensate drain lines with other drain or discharge lines into a single (common) pipe or line. Each line (condensate drain line, temperature and pressure relief valve discharge pipe, etc) should be independently run to an adequate drain.

Slope the condensate drain lines toward the inside floor drain or condensate pump.

The condensate drain lines and connections to the drain piping must comply with all local codes.

Use appropriate primer and glue to cement the condensate drain lines to the heat pump drain pan. NOTE: The heat

pump drain pan is ABS and the two condensate drain pipes should be PVC.

If a condensate pump is installed it should shut off the heat pump in the event the condensate pump fails or the float switch in the pump activates (See "Condensate Pump Installation" section.)

T & P Valve and Pipe Insulation

NOTE: Your water heater is insulated to minimize heat loss from the tank. Further reduction in heat loss can be

accomplished by insulating the hot water lines from the water heater.

1.Locate the temperature and pressure relief valve on the water heater (also known as a T&P relief valve). See Figure 10.

2.Locate the slit running the length of the T&P relief valve insulation.

3.Spread the slit open and fit the insulation over the T&P relief valve. See Figure 10. Apply gentle pressure to the insulation to ensure that it is fully seated on the T&P Relief Valve. Once seated, secure the insulation with duct tape, electrical tape, or equivalent. IMPORTANT: The insulation and tape must not block the discharge opening or hinder access to the manual relief lever (Figure 10). Ensure a discharge pipe is installed into the T&P valve discharge opening per the instructions in this manual.

4.Locate the hot water (outlet) & cold water (inlet) pipes to the water heater.

5.Locate the slit running the length of a section of pipe insulation.

6.Spread the slit open and slip the insulation over the cold water (inlet) pipe. Apply gentle pressure along the length of the insulation to ensure that it is fully seated around the pipe. Also, ensure that the base of the insulation is flush with the water heater. Once seated, secure the insulation with duct tape, electrical tape, or equivalent.

7.Repeat steps 5 and 6 for the hot water (outlet) pipe.

8.Add additional sections of pipe insulation as needed.

T&P Relief Valve Insulation

veXef Lever

Relief Valve

Drain Line

FIGURE 10.

11