Operating Mode Descriptions
The operating modes can be changed by touching the desired
mode icon on the User Interface Module (see Figure 16.) NOTE: All buttons on the User Interface are touch sensitive and
require only a light touch to actuate.
®Hybrid Mode - This is the default, recommended setting. Combining high energy efficiency with
HyE3R4D | reduced recovery time, this mode uses the heat | |||
| ||||
| pump as the primary heating source. The heating | |||
| element wilt heat water if demand exceeds | |||
| a predetermined level so that the set point | |||
| temperature can be recovered more quickly. |
| ||
| Efficiency Mode - Is the most energy efficient | |||
| mode. This mode uses the heat pump to heat water | |||
| in the tank. The elements are not used unless the | |||
| ambient operating temperature is below 45°F or | |||
| above 109°F. If hot water demands are not met in | |||
| Efficiency Mode it may be necessary to switch to | |||
| Hybrid Mode. |
|
|
|
© | Electric Mode - The water | heater | functions | as a |
conventional electric unit, | relying | totally on | the |
ELECTRIC | elements to heat the water in the tank. This mode |
| may be useful in winter to eliminate the output of |
| cold air from the unit. |
| Vacation Mode - The controller adjusts the water |
| temperature to approximately 60°F. This mode is |
| recommended when the water heater is not in use |
| for a tong period of time. This mode effectively |
| turns the controller temperature setting down to a |
| temperature that prevents the water in the water |
| heater from freezing while still conserving energy. |
| NOTE: To activate the Vacation Mode touch the |
| vacation button. To deactivate Vacation Mode |
| touch the vacation button. IMPORTANT: The |
| anode protecting the tank requires power to the |
| unit to operate. Do not shut off power to the unit |
| for extended periods of time. If power must be |
| turned off for an extended period of time, drain the |
| tank completely. |
| Lock - Holding this button for more than 3 seconds |
| switches the lock mode on or off. When the User |
| Interface Module is locked a symbol and "Lock" |
| text will be visible on the display (see Figure 16). |
| °F/°C - The button switches the display to show |
| the set temperature in Fahrenheit or Celsius. |
Operational Mode Buttons
| Water |
|
| Temperature | |
Element |
|
|
Functioning |
|
|
Icon | Water | Heater |
I _ | ||
I._ | - Mode/Status | |
| Indicator | |
| ,,Water | Heater |
| Efficiency Status | |
| Icon |
|
Heat Pump |
|
|
Functioning |
|
|
Icon | LCD Control | |
| ||
| Temperature | |
Up (Increase) | (Decrease) | |
Button | Button |
|
Fahrenheit/Celsius | Display Panel | |
| ||
Temperature Display | Lock Button |
|
Button |
|
|
Power Button: On - Green
Standby - Red
FIGURE 16.
Temperature-Pressure Relief Valve Operation
The
•Burn hazard
•Hotwater discharge.
•Keep hands clear of drain valve discharge.
The
(1)no one is in front of or around the outlet of the temperature- pressure relief valve discharge line, and (2) the water manually discharged wilt not cause any property damage or bodily injury. The water may be extremely hot.
DISCHARGE PIPE
FIGURE 17.
17