Inspection/Cleaning of the Condensate Drain

2.Remove (slide) the filter from the unit.

3.If you are replacing the filter skip to step 4. To clean the filter use a vacuum with a hose attachment to remove any dust or debris.

4.Place the new or cleaned filter into the water heater and secu re the filter to the shroud with the screw loosened earlier. NOTE: Use the guides/slots when inserting the filter into the water heater.

5.Restore power to the water heater and press the power button to turn the water heater on. NOTE: The water heater will conduct a system diagnostic check prior to operation.

Inspection/Cleaning of the Condensate Drain

Pan & Condensate Drain Lines

IMPORTANT: Before attempting to clean or replace the condensate drain pan or lines press the power button to place the water heater in Standby Mode and shut-off power to the water heater at the circuit breaker/fuse box.

1.Remove the access panel (fan side) by loosening the screws securing it to the unit.

2.Check the condensate drain pan and drain lines for any dirt or debris that might interfere with proper drainage. Wipe out any dirt or debris with a damp cloth.

3.Once the condensate drain pan and lines have been inspected/cleaned, secure the access panel to the water heater.

4.Restore power to the water heater and press the power button to turn the water heater on. NOTE: The water heater will conduct a system diagnostic check prior to operation.

Drain Valve Washer Replacement

Before removing any access panels or servicing the water heater, make sure the electrical

supply to the water heater is turned "OFF".

Failure to do this could result in death, serious bodily injury, or property damage.

NOTE: For replacement, use a 17/32" x 13/64" x 1/8" thick washer available at your nearest hardware store.

Before beginning turn "OFF" the electrical power supply to the water heater.

Follow Draining instructions. See Draining section.

Turning counter clockwise, remove the hex cap below the screw handle.

Remove the washer and put the new one in place.

Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.

Follow Filling the Water Heater instructions in the Installation Instructions section.

Check for leaks.

Turn "ON" electric power to the water heater.

WASHER

FIGURE 21.

Service

Before calling for repair service, read the Start Up Conditions and Operational Conditions found in the Troubleshooting section of this manual.

If a condition persists or you are uncertain about the operation of the water heater, let a qualified person check it out.

Contact Sears Repair Services at 1-800-4-MY-HOME ®